Nafion/lead nitroprusside nanoparticles modified carbon ceramic electrode as a novel amperometric sensor for L-cysteine

被引:62
作者
Razmi, H. [1 ]
Heidari, H. [1 ]
机构
[1] Azarbaijan Univ Tarbiat Moallem, Fac Sci, Electrochem Res Lab, Tabriz, Iran
关键词
Lead nitroprusside; L-Cysteine; Sol-gel; Carbon ceramic; Nafion; Electrocatalysis; FILM-MODIFIED ELECTRODE; MODIFIED ALUMINUM ELECTRODE; ELECTROCATALYTIC OXIDATION; LIQUID-CHROMATOGRAPHY; PENTACYANONITROSYLFERRATE FILM; COBALT HEXACYANOFERRATE; N-ACETYLCYSTEINE; PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; SULFHYDRYL COMPOUNDS;
D O I
10.1016/j.ab.2009.01.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work describes the electrochemical and electrocatalytic properties of carbon ceramic electrode (CCE) modified with lead nitroprusside (PbNP) nanoparticles as a new electrocatalyst material. The structure of deposited film on the CCE was characterized by energy dispersive X-ray (EDX), Fourier transform infrared (FTIR), and scanning electron microscopy (SEM). The cyclic voltammogram (CV) of the PbNP modified CCE showed two well-defined redox couples due to [Fe(CN)(5)NO](3-)/[Fe(CN)(5)NO](2-) and Pb(IV)/Pb(II) redox reactions. The modified electrode showed electrocatalytic activity toward the oxidation Of L-Cysteine and was used as an amperometric sensor. Also, to reduce the fouling effect of L-cysteine and its oxidation products on the modified electrode, a thin film of Nafion was coated on the electrode surface. The sensor response was linearly changed with L-cysteine concentration in the range of 1 X 10(-6) to 6.72 X 10(-5) mol L(-1) with a detection limit (signal/noise ratio [S/N] = 3) of 0.46 mu M. The sensor sensitivity was 0.17 mu A (mu M)(-1) and some important advantages Such as simple preparation, fast response, good stability, interference-free signals, antifouling properties, and reproducibility of the sensor for amperometric determination Of L-Cysteine were achieved. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:15 / 22
页数:8
相关论文
共 54 条
[1]   Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[2]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[3]   Electrocatalytic oxidation of nitric oxide at indium hexacyanoferrate film-modified electrodes [J].
Casero, E ;
Pariente, F ;
Lorenzo, E .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (02) :294-299
[4]   SPECTROPHOTOMETRIC CYSTEINE ANALYSIS [J].
CAVINS, JF ;
INGLETT, GE ;
KRULL, LH ;
FRIEDMAN, M ;
GIBBS, DE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1972, 20 (06) :1124-&
[5]  
Chen H.L., 1999, STRUCTURE FUNCTION B
[6]   The bioelectrocatalytic properties of cytochrome C by direct electrochemistry on DNA film modified electrode [J].
Chen, SM ;
Chen, SV .
ELECTROCHIMICA ACTA, 2003, 48 (05) :513-529
[7]   Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide [J].
Chwatko, G ;
Bald, E .
TALANTA, 2000, 52 (03) :509-515
[8]   BIOCHEMISTRY OF SULFUR-CONTAINING AMINO-ACIDS [J].
COOPER, AJL .
ANNUAL REVIEW OF BIOCHEMISTRY, 1983, 52 :187-222
[9]   Potentiometric detection of thiols: a mechanistic evaluation of quinone-thiol interactions [J].
Digga, A ;
Gracheva, S ;
Livingstone, C ;
Davis, J .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (08) :732-736
[10]   HIV-INDUCED CYSTEINE DEFICIENCY AND T-CELL DYSFUNCTION - A RATIONALE FOR TREATMENT WITH N-ACETYLCYSTEINE [J].
DROGE, W ;
ECK, HP ;
MIHM, S .
IMMUNOLOGY TODAY, 1992, 13 (06) :211-214