Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders

被引:43
|
作者
Feng, XB [1 ]
Sommar, J
Gårdfeldt, K
Lindqvist, O
机构
[1] Univ Gothenburg, Dept Chem, S-41296 Gothenburg, Sweden
[2] Acad Sinica, Inst Geochem, State Key Lab Environm Geochem, Guiyang 550002, Peoples R China
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 05期
关键词
D O I
10.1007/s002160050086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved method for the determination of gaseous divalent mercury (GDM) in ambient air using KCl coated denuders has been developed and tested. GDM collected in the KCl coated denuders can be quantitatively desorbed at 450 degrees C in 10 min. After being complete thermally reduced to Hg-0 at 900 degrees C, all mercury released from the denuder is pre-concentrated on the analytical Au trap, and detected by cold vapor atomic fluorescence spectrometry (CVAFS). The absolute detection limit of the method is less than 3 pg. Preliminary data of GDM concentration in ambient air from different sampling stations show that GDM concentrations in the urban air of Goteborg are much higher than in rural air (Rorvik and Sasetta), which indicates the anthropogenic origin of GDM.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 50 条
  • [1] Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Xinbin Feng
    J. Sommar
    K. Gårdfeldt
    O. Lindqvist
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 423 - 428
  • [2] Determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Feng, XB
    Sommar, J
    Lindqvist, O
    Zhu, YX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 682 - 685
  • [3] Sampling and determination of gas phase divalent mercury in the air using a KCl coated denuder
    Xiao, Z
    Sommar, J
    Wei, S
    Lindqvist, O
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03): : 386 - 391
  • [4] Sampling and determination of gas phase divalent mercury in the air using a KCl coated denuder
    Z. Xiao
    J. Sommar
    S. Wei
    O. Lindqvist
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 386 - 391
  • [5] SAMPLING AND DETERMINATION OF GASEOUS AND PARTICULATE MERCURY IN THE ATMOSPHERE USING GOLD-COATED DENUDERS
    XIAO, ZF
    MUNTHE, J
    LINDQVIST, O
    WATER AIR AND SOIL POLLUTION, 1991, 56 : 141 - 151
  • [6] Uncertainties of Gaseous Oxidized Mercury Measurements Using KCl-Coated Denuders, Cation-Exchange Membranes, and Nylon Membranes: Humidity Influences
    Huang, Jiaoyan
    Gustin, Mae Sexauer
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (10) : 6102 - 6108
  • [7] Development of a diffusion type of Reactive Gaseous Mercury (RGM) source and evaluation of the RGM collecting efficiency by KCl-coated annular denuders
    Julia, YL
    Feng, X
    Hao, Y
    Banic, C
    Schroeder, WH
    JOURNAL DE PHYSIQUE IV, 2003, 107 : 1431 - 1431
  • [8] Comparison of Gaseous Oxidized Hg Measured by KCl-Coated Denuders, and Nylon and Cation Exchange Membranes
    Huang, Jiaoyan
    Miller, Matthieu B.
    Weiss-Penzias, Peter
    Gustin, Mae Sexauer
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (13) : 7307 - 7316
  • [9] Development and characterization of an annular denuder methodology for the measurement of divalent inorganic reactive gaseous mercury in ambient air
    Landis, MS
    Stevens, RK
    Schaedlich, F
    Prestbo, EM
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (13) : 3000 - 3009
  • [10] Measurement of Particulate Bound Mercury, Gaseous Elemental Mercury, and Reactive Gaseous Mercury Concentrations by Using an Ambient Air Mercury Collection System
    Fang, Guor-Cheng
    Kuo, Yu-Chen
    Zhuang, Yuan-Jie
    Cho, Meng-Hsien
    ENVIRONMENTAL FORENSICS, 2015, 16 (04) : 305 - 309