Gold nanoparticle-labeled detection antibodies for use in an enhanced electrochemical immunoassay of hepatitis B surface antigen in human serum

被引:26
|
作者
Wu, Sheng [1 ]
Zhong, Zhaoyang [2 ]
Wang, Dong [2 ]
Li, Mengxia [2 ]
Qing, Yi [2 ]
Dai, Nan [2 ]
Li, Zengpeng [2 ]
机构
[1] 101th Hosp Chinese Peoples Liberat Army, Dept Hepatobiliary Surg, Wuxi 214044, Peoples R China
[2] Third Mil Med Univ, Daping Hosp, Inst Surg Res, Dept Canc Ctr, Chongqing 400042, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical immunosensor; Bio-barcode; Nanogold particles; Hepatitis B; Surface antigen; Sandwich-type enzyme immunoassay; CARCINOEMBRYONIC ANTIGEN; IMMUNOSENSOR; DNA; IMMOBILIZATION; POPULATION; NANOLABELS; INTERFACE; BIOSENSOR; ELECTRODE; MATRICES;
D O I
10.1007/s00604-009-0184-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of gold nanoparticle-based electrochemical immunoassays have been extensively studied for the detection of hepatitis B surface antigen (HBsAg), but most often they exhibit low sensitivity. We describe the fabrication of a new electrochemical immunoassay for signal amplification of the antigen-antibody reaction combined with the nanogold-based bio-barcode technique. Hepatitis B surface antibody (HBsAb) was initially immobilized on a nanogold/thionine/DNA-modified gold electrode, and then a sandwich-type immunoassay format was employed for the detection of HBsAg using nanogold-codified horseradish peroxidase-HBsAb conjugates as secondary antibodies. Under optimal conditions, the current response of the sandwich-type immunocomplex relative to the H2O2 system was proportional to HBsAg concentration in the range from 0.5 to 650 ng center dot mL(-1) with a detection limit of 0.1 ng center dot mL(-1) (S/N = 3). The precision, reproducibility and stability of the immunosensor were acceptable. Subsequently, the immunosensors were used to assay HBsAg in human serum specimens. Analytical results were in agreement with those obtained by the standard chemiluminescence enzyme-linked immunosorbent assay.
引用
收藏
页码:269 / 275
页数:7
相关论文
共 50 条
  • [41] Hepatitis B surface antigen mutant detection on four immunoassay analysers.
    Saw, SL
    Aw, TC
    CLINICAL CHEMISTRY, 2000, 46 (06) : A53 - A53
  • [42] POSSIBILITIES OF DETECTION OF ANTIBODIES DIRECTED AGAINST HEPATITIS-B SURFACE-ANTIGEN USING ENZYME-IMMUNOASSAY
    SCHMECHTA, H
    PORSTMANN, T
    PORSTMANN, B
    SEIFERT, R
    MEISEL, H
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1982, 37 (01): : 24 - 27
  • [43] DEVELOPMENT OF AN ENZYME-IMMUNOASSAY FOR THE DETECTION OF HEPATITIS-B SURFACE-ANTIGEN EMPLOYING MONOCLONAL-ANTIBODIES
    TOPLIKAR, E
    CARLOMAGNO, A
    ROJKIN, LF
    GARIGLIO, R
    LORENZO, LE
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (06) : 324 - 328
  • [44] COINCIDENT HEPATITIS-B SURFACE-ANTIGEN AND ANTIBODIES OF DIFFERENT SUBTYPES IN HUMAN-SERUM
    TABOR, E
    GERETY, RJ
    SMALLWOOD, LA
    BARKER, LF
    JOURNAL OF IMMUNOLOGY, 1977, 118 (01): : 369 - 370
  • [45] IMMUNOASSAY FOR HEPATITIS-B SURFACE-ANTIGEN (HBSAG) USING ENHANCED LUMINESCENCE
    SPILLER, GH
    TOVEY, KC
    MCINTYRE, A
    WESTON, S
    SHEPHERD, H
    GRIFFIN, J
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1089 - 1089
  • [46] Comparison of CuO nanoparticle and CuO/MWCNT nanocomposite for amplification of chemiluminescence immunoassay for detection of the hepatitis B surface antigen in biological samples
    Ehsania, Mahjoobeh
    Chaichi, Mohammad Javad
    Hosseini, S. Nezammeddin
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 319 - 328
  • [47] Facile preparation of carbon nanotube-conducting polymer network for sensitive electrochemical immunoassay of Hepatitis B surface antigen in serum
    Hu, Yaogai
    Zhao, Zhengyu
    Wan, Qianqian
    BIOELECTROCHEMISTRY, 2011, 81 (02) : 59 - 64
  • [48] MICROPARTICLE ENZYME-IMMUNOASSAY FOR THE MEASUREMENT OF ANTIBODIES TO HEPATITIS-B SURFACE-ANTIGEN
    OSTROW, DH
    IRACE, H
    MACIOSZEK, J
    SWANSON, SM
    EDWARDS, BM
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1193 - 1193
  • [49] Comparing Assay Performance of ELISA and Chemiluminescence Immunoassay in Detecting Antibodies to Hepatitis B Surface Antigen
    Madiyal, Mridula
    Sagar, Siddharth
    Vishwanath, Shashidhar
    Banerjee, Barnini
    Eshwara, Vandana Kalwaje
    Chawla, Kiran
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (11) : DC22 - DC25
  • [50] Highly sensitive detection of cardiac troponin I in human serum using gold nanoparticle-based enhanced sandwich immunoassay
    Kim, Wan-Joong
    Cho, Hyo Young
    Kim, Bong Kyu
    Huh, Chul
    Chung, Kwang Hyo
    Ahn, Chang-Geun
    Kim, Young Jun
    Kim, Ansoon