Data Driven Respiratory Signal Detection in PET Taking Advantage of Time-of-Flight Data

被引:0
作者
Bertolli, Ottavia [1 ]
Arridge, Simon [2 ]
Stearns, Charles W. [4 ]
Wollenweher, Scott D. [4 ]
Hutton, Brian F. [1 ,3 ]
Thielemans, Kris [1 ]
机构
[1] UCLH, Inst Nucl Med, 235 Euston Rd,T-5, London NW1 2BU, England
[2] UCL, Ctr Med Image Comp, Gower St, London WC1E 6BT, England
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[4] GE Healthcare, Waukesha, WI USA
来源
2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD) | 2016年
基金
英国工程与自然科学研究理事会;
关键词
TOF PET; respiratory motion; data driven gating; PCA;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory gating is a powerful tool for tackling motion-related issues in chest PET imaging. On current scanners the respiratory signal is obtained from external devices, whereas with Data-Driven methods it can be extracted directly from the data. The aim of this work is to show the increased potential of the application of Principal Component Analysis (PCA) on TOF data. We propose a methodology that retains the TOF information and compare it to the non-TOF method. We tested the method on 16 FDG oncology patients, monitored with an RPM camera. To further investigate the benefit of TOF, PCA was selectively applied to sets of TOF bins equidistant from the center. The correlation with the RPM, the level of noise and the respiratory-likeness were analysed for all the obtained respiratory signals. The results of our analysis showed that retaining the TOF information into the sinograms considerably increased the quality of the extracted respiratory signals.
引用
收藏
页数:3
相关论文
共 5 条
  • [1] Physical Performance of the new hybrid PET/CT Discovery-690
    Bettinardi, V.
    Presotto, L.
    Rapisarda, E.
    Picchio, M.
    Gianolli, L.
    Gilardi, M. C.
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5394 - 5411
  • [2] On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework
    Kesner A.L.
    Schleyer P.J.
    Büther F.
    Walter M.A.
    Schäfers K.P.
    Koo P.J.
    [J]. EJNMMI Physics, 1 (1) : 1 - 11
  • [3] Thielemans K, 2011, IEEE NUCL SCI CONF R, P3904, DOI 10.1109/NSSMIC.2011.6153742
  • [4] Recent developments in time-of-flight PET
    Vandenberghe, S.
    Mikhaylova, E.
    D'Hoe, E.
    Mollet, P.
    Karp, J. S.
    [J]. EJNMMI PHYSICS, 2016, 3 (01):
  • [5] Wang MD, 2015, IEEE ENG MED BIO, P4520, DOI 10.1109/EMBC.2015.7319399