摘要
This paper presents a concept of an endomicroscope for an early detection of neoplastic lesions in the human stomach tissue, based on the swept source optical coherence tomography (SS-OCT) and a measurement probe with integrated Mirau micro interferometer. The system consists of pigtailed illumination and detection blocks, connected via a Gradient Index (GRIN) lens collimator to a micro-opto-electro-mechanical systems (MOEMS) measurement probe (4 mm x 4 mm x 20 mm). The technology of Mirau micro interferometer is based on vertical multi-wafer bonding approach. The MOEMS probe is intended to be mounted on a continuum robot arm to perform in vivo microscopy of stomach tissues. First, the optical design of the SS-OCT endomicroscope is described, including an analysis of sensitivity. Then, we focus on the fabrication technologies and optical characterization of a key component of the Mirau micro interferometer, i.e., monolithically integrated focusing glass lens. SS-OCT endomicroscope will provide a fast axial scanning of tissues with A-scan sweep rate of 110 kHz, offering the axial resolution of 5.2 mu m and the lateral resolution of 10.2 mu m.
引用
收藏
页码:7061 / 7070
页数:10
相关论文
共 28 条
[1]   Micromachined array-type Mirau interferometer for parallel inspection of MEMS [J].
Albero, J. ;
Bargiel, S. ;
Passilly, N. ;
Dannberg, P. ;
Stumpf, M. ;
Zeitner, U. D. ;
Rousselot, C. ;
Gastinger, K. ;
Gorecki, C. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (06)
[2]  
Albero J., 2014, P SOC PHOTO-OPT INS, V9230
[3]  
Aljasem K., 2008, J OPT A-PURE APPL OP, V10, P1
[4]   A simple method for quality evaluation of micro-optical components based on 3D IPSF measurement [J].
Baranski, Maciej ;
Perrin, Stephane ;
Passilly, Nicolas ;
Froehly, Luc ;
Albero, Jorge ;
Bargiel, Sylwester ;
Gorecki, Christophe .
OPTICS EXPRESS, 2014, 22 (11) :13202-13212
[5]   Wafer-Level Fabrication of Microcube-Typed Beam-Splitters by Saw-Dicing of Glass Substrate [J].
Baranski, Maciej ;
Bargiel, Sylwester ;
Passilly, Nicolas ;
Guichardaz, Blandine ;
Herth, Etienne ;
Gorecki, Christophe ;
Jia, Chenping ;
Froemel, Joerg ;
Wiemer, Maik .
IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (01) :100-103
[6]  
Bashkatov A.N., 2007, Med. Laser Appl, V22, P95, DOI DOI 10.1016/J.MLA.2007.07.003
[7]   Assessment of the flow velocity of blood cells in a microfluidic device using joint spectral and time domain optical coherence tomography [J].
Bukowska, Danuta M. ;
Derzsi, Ladislav ;
Tamborski, Szymon ;
Szkulmowski, Maciej ;
Garstecki, Piotr ;
Wojtkowski, Maciej .
OPTICS EXPRESS, 2013, 21 (20) :24025-24038
[8]  
Chikhaoui MT, 2014, ADVANCES IN ROBOT KINEMATICS, P457, DOI 10.1007/978-3-319-06698-1_47
[9]   Optical coherence tomography today: speed, contrast, and multimodality [J].
Drexler, Wolfgang ;
Liu, Mengyang ;
Kumar, Abhishek ;
Kamali, Tschackad ;
Unterhuber, Angelika ;
Leitgeb, Rainer A. .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
[10]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI [10.1088/0034-4885/66/2/204, 10.2184/lsj.31.635]