Regionally Optimized Reconstruction for Partially Parallel Imaging in MRI Applications

被引:3
作者
Li, Yu [1 ]
Huang, Feng [1 ]
机构
[1] Invivo Diagnost Imaging, Gainesville, FL 32608 USA
关键词
Coil array; GRAPPA; partially parallel imaging; regionally optimized reconstruction; SENSE; COIL; ARRAY;
D O I
10.1109/TMI.2008.2010432
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Based on the conventional SENSE and GRAPPA, a regionally optimized reconstruction method is developed for reduced noise and artifact level in partially parallel imaging. In this regionally optimized reconstruction, the field-of-view (FOV) is divided into a number of small regions. Over every small region, the noise amplification and data fitting error can be balanced and minimized locally by taking advantage of spatial correlation of neighboring pixels in reconstruction. The full FOV image can be obtained by "region-by-region" reconstruction. Compared with the conventional SENSE, this method gives better performance in the regions where there are pixels with high SENSE g-factors. Compared with GRAPPA, it is better in the regions where all the pixels have low SENSE g-factors. In this work, we applied the regionally optimized reconstruction in four important imaging experiments: brain, spine, breast, and cardiac. It was demonstrated in these experiments that the overall image quality using this regionally optimized reconstruction is better than that using the conventional SENSE or GRAPPA.
引用
收藏
页码:687 / 695
页数:9
相关论文
共 50 条
[41]   Fast parallel image reconstruction using smacker for functional magnetic resonance imaging [J].
Tieng, Quang M. ;
Vegh, Viktor ;
Cowin, Gary J. ;
Yang, Zhengyi .
2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, :564-567
[42]   Improved parallel magnetic resonance imaging reconstruction with multiple variable density sampling [J].
Sheng, Jinhua ;
Shi, Yuchen ;
Zhang, Qiao .
SCIENTIFIC REPORTS, 2021, 11 (01) :9005
[43]   A dual-interpolator method for improving parallel MRI reconstruction [J].
Chang, Yuchou ;
Pham, Huy Anh ;
Li, Zhiqiang .
MAGNETIC RESONANCE IMAGING, 2022, 92 :108-119
[44]   Spatio-temporal wavelet regularization for parallel MRI reconstruction: application to functional MRI [J].
Chaari, Lotfi ;
Ciuciu, Philippe ;
Meriaux, Sebastien ;
Pesquet, Jean-Christophe .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (06) :509-529
[45]   Reliability of MRI-derived cortical and subcortical morphometric measures: Effects of pulse sequence, voxel geometry, and parallel imaging [J].
Wonderlick, J. S. ;
Ziegler, D. A. ;
Hosseini-Varnamkhasti, P. ;
Locascio, J. J. ;
Bakkour, A. ;
Van der Kouwe, A. ;
Triantafyllou, C. ;
Corkin, S. ;
Dickerson, B. C. .
NEUROIMAGE, 2009, 44 (04) :1324-1333
[46]   HF-SENSE: an improved partially parallel imaging using a high-pass filter [J].
Zhang, Jucheng ;
Chu, Yonghua ;
Ding, Wenhong ;
Kang, Liyi ;
Xia, Ling ;
Jaiswal, Sanjay ;
Wang, Zhikang ;
Chen, Zhifeng .
BMC MEDICAL IMAGING, 2019, 19 (1)
[47]   Description of parallel imaging in MRI using multiple coils [J].
Wang, Y .
MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (03) :495-499
[48]   Functional MRI using regularized parallel imaging acquisition [J].
Lin, FH ;
Huang, TY ;
Chen, NK ;
Wang, FN ;
Stufflebeam, SM ;
Belliveau, JW ;
Wald, LL ;
Kwong, KK .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :343-353
[49]   PIC-GAN: A Parallel Imaging Coupled Generative Adversarial Network for Accelerated Multi-Channel MRI Reconstruction [J].
Lv, Jun ;
Wang, Chengyan ;
Yang, Guang .
DIAGNOSTICS, 2021, 11 (01)
[50]   Comparison of image reconstruction algorithms on parallel MRI - art. no. 67891B [J].
Huang, Min .
MIPPR 2007: MEDICAL IMAGING, PARALLEL PROCESSING OF IMAGES, AND OPTIMIZATION TECHNIQUES, 2007, 6789 :B7891-B7891