COMPARISON OF SINGLE-SLICE COMPUTED TOMOGRAPHY PROTOCOLS FOR DETECTION OF PULMONARY NODULES IN DOGS

被引:15
作者
Joly, Hugo [1 ]
d'Anjou, Marc-Andre [1 ]
Alexander, Kate [1 ]
Beauchamp, Guy [1 ]
机构
[1] Univ Montreal, Fac Med Vet, Dept Clin Sci, Compan Anim Res Grp, St Hyacinthe, PQ J2S 7C6, Canada
关键词
CT protocols; dogs; pulmonary nodules; IMAGE-DATABASE-CONSORTIUM; SPIRAL CT; HELICAL CT; DISEASE; IDENTIFICATION;
D O I
10.1111/j.1740-8261.2009.01534.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Two dogs (4 and 38 kg) with radiographic evidence of pulmonary nodules were evaluated using single-slice, helical computed tomography (CT). Each thorax was scanned using 12 combinations of examination parameters that included slice collimation width (3 and 5 mm for the small dog and 5 and 7 mm for the large dog), pitch (1, 1.5, and 2), and reconstruction interval (0.5 and 1). Sensitivity, specificity, and accuracy for nodule detection were evaluated for each protocol by three different observers, their results being compared with a consensus evaluation of images acquired with the protocol providing the best theoretic resolution (narrow collimation, pitch of 1, reconstruction interval of 0.5). For all observers, sensitivity and accuracy were significantly increased when using a protocol with narrow collimation (P < 0.0001-0.005 and P=0.0003-0.005, respectively). Pitch and reconstruction interval did not significantly influence the accuracy, sensitivity, or specificity for at least two of the observers. Additionally, nodule size (< 3 mm vs. >= 3 mm) did not significantly affect nodule detection. Interobserver repeatability was variable among protocols (kappa=0.32-0.78), highlighting the fact that nodule detection may be more dependent on the observer than on the choice of the CT protocol. For single-slice CT, the results of this study suggest that narrow collimation (3-5 mm, depending on the animal's size), a pitch of 2 and a reconstruction interval of 1 should be used in dogs for the detection of pulmonary nodules.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 21 条
[1]   The Lung Image Database Consortium (LIDC): An evaluation of radiologist variability in the identification of lung nodules on CT scans [J].
Armato, Samuel G., III ;
McNitt-Gray, Michael F. ;
Reeves, Anthony P. ;
Meyer, Charles R. ;
McLennan, Geoffrey ;
Aberle, Denise R. ;
Kazerooni, Ella A. ;
MacMahon, Heber ;
van Beek, Edwin J. R. ;
Yankelevitz, David ;
Hoffman, Eric A. ;
Henschke, Claudia I. ;
Roberts, Rachael Y. ;
Brown, Matthew S. ;
Engelmann, Roger M. ;
Pais, Richard C. ;
Piker, Christopher W. ;
Qing, David ;
Kocherginsky, Masha ;
Croft, Barbara Y. ;
Clarke, Laurence P. .
ACADEMIC RADIOLOGY, 2007, 14 (11) :1409-1421
[2]   Lung image database consortium: Developing a resource for the medical imaging research community [J].
Armato, SG ;
McLennan, G ;
McNitt-Gray, MF ;
Meyer, CR ;
Yankelevitz, D ;
Aberle, DR ;
Henschke, CI ;
Hoffman, EA ;
Kazerooni, EA ;
MacMahon, H ;
Reeves, AP ;
Croft, BY ;
Clarke, LP .
RADIOLOGY, 2004, 232 (03) :739-748
[3]   Optimal section spacing in single-detector helical CT [J].
Brink, JA ;
Wang, G ;
McFarland, EG .
RADIOLOGY, 2000, 214 (02) :575-578
[4]   Effect of breathing on the detection of in vivo simulated pulmonary nodules by spiral CT [J].
Coakley, FV ;
Cohen, MD ;
Johnson, MS ;
Gonin, R ;
Hanna, MP .
CLINICAL RADIOLOGY, 1998, 53 (07) :506-509
[5]   Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT [J].
Coakley, FV ;
Cohen, MD ;
Waters, DJ ;
Davis, MM ;
Karmazyn, B ;
Gonin, R ;
Hanna, MP .
PEDIATRIC RADIOLOGY, 1997, 27 (07) :576-579
[6]  
Dawson-Saunders B., 2001, PROPORTIONS SAME GRO, V3rd, P115
[7]   Comparison of radiographic and computed tomography lymphangiography for identification of the canine thoracic duct [J].
Esterline, ML ;
Radlinsky, MG ;
Biller, DS ;
Mason, DE ;
Roush, JK ;
Cash, WC .
VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (05) :391-395
[8]   Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[9]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[10]  
KALENDER WA, 2005, DOSE COMPUTED TOMOGR, P154