Quantitation of trimethyl amine by headspace gas chromatography-mass spectrometry using a base-modified column

被引:5
作者
Bir, D [1 ]
Tutin, K [1 ]
机构
[1] Georgia Pacif Resins Inc, Decatur, GA 30035 USA
关键词
Column chromatography - Gas chromatography - Glass fibers - Mass spectrometry - Principal component analysis;
D O I
10.1093/chromsci/40.6.337
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Headspace gas chromatography-mass spectrometry (GC-MS) has been successfully applied to the analysis of the highly volatile species trimethyl amine (TMA). TMA quantitation in fiberglass insulation resins (ultimately used by the automotive and building products industries) is of interest because of its highly odoriferous nature. The release of TMA from fiberglass insulation products is the principal component responsible for the "fishy" odor encountered in automobiles. Currently, the industry standard for the analysis of TMA involves injecting an aqueous insulation extract into the GC-MS equipped with a polyethylene glycol column. Several problems inherent in this analysis prohibit consistent performance and enhance the possibility for wide variations in the quantitative results. This article reports the development of a new approach to the quantitation of TMA from fiberglass insulation between the levels of 1 and 150 ppm.
引用
收藏
页码:337 / 342
页数:6
相关论文
共 14 条