New method to assess the registration of CT-MR images of the head

被引:4
|
作者
Pappas, IP
Puja, M
Styner, M
Liu, J
Caversaccio, M
机构
[1] Univ Bern, ME Res Ctr, CH-3001 Bern, Switzerland
[2] Univ Bern, Inselspital, ORL Dept, CH-3001 Bern, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2004年 / 35卷
关键词
CT; MR; fusion; registration; assessment;
D O I
10.1016/j.injury.2004.05.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. However, registration errors, either global or local, are common and are non-uniform within the image volume. In this paper, we propose a new algorithm that assesses the quality of the registration locally within the CT-MR volume and provides visual, color-coded feedback to the user about the location and extent of good and bad correspondence between the two images. The proposed registration assessment algorithm is based on a correspondence analysis of bone structures in the CT and MR images. For that purpose, a custom segmentation algorithm for bone in MR images has been developed that is based on a stochastic threshold computation method. This segmentation method for MR images and the CT-MR registration assessment algorithm were validated on simulated MR datasets and real CT-MR image pairs of the head. Some partial-volume effects occur at the borders of the bone structures and at the bone interfaces with air, which cannot be separated from bone in the MR image. The presented assessment method of CT-MR image registration offers the user a new tool, to evaluate the overall and local quality of the registration. With this information, the user does not have to blindly trust the fused CT-MR datasets but can easily identify areas of inaccurate correspondence. The application of the algorithm is so far limited to T1-weighted MR and CT images of the head area.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [1] New method to assess the registration of CT-MR images of the head
    Pappas, IP
    Malik, P
    Styner, M
    Liu, JB
    Caversaccio, M
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 129 - 136
  • [2] Automatic method to assess local CT-MR Imaging registration accuracy on images of the head
    Pappas, IPI
    Styner, M
    Malik, P
    Remonda, L
    Caversaccio, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (01) : 137 - 144
  • [3] Automatic 3D Registration of CT-MR Head and Neck Images With Surface Matching
    Chu, Qin
    Zhan, Yinwei
    Guo, Fanqing
    Song, Mengchun
    Yang, Rongqian
    IEEE ACCESS, 2019, 7 : 78274 - 78280
  • [4] CT-MR image nonrigid registration
    Palos, G
    Betrouni, N
    Vermandel, M
    Devlaminck, V
    Rousseau, J
    PROCEEDINGS OF THE SECOND IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2004, : 170 - 173
  • [5] Registration Method for CT-MR Image Based on Mutual Information
    张红颖
    张加万
    孙济洲
    Transactions of Tianjin University, 2007, (03) : 226 - 230
  • [6] A fast and accurate method for registration of MR images of the head
    Kotsas, P
    Malasiotis, S
    Strintzis, M
    Piraino, DW
    Cornhill, JF
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 1998, 52 (1-3) : 167 - 182
  • [7] A new automated method for three-dimensional registration of MR images of the head
    Kotsas, P
    Strintzis, M
    Piraino, DW
    MEDICAL INFORMATICS EUROPE '97: PARTS A & B, 1997, 43 : 507 - 511
  • [8] Investigation of normalized mutual information for co-registration of CT-MR images of permanent prostate implants
    Vidakovic, S
    Sloboda, R
    MEDICAL PHYSICS, 2005, 32 (07) : 2414 - 2415
  • [9] CT-MR Image Registration in Liver Treatment by Maximization of Mutual Information
    Huang, Xiaoyang
    Wang, Boliang
    Liu, Ruhuan
    Wang, Xiaoping
    Wu, Zhijian
    2008 IEEE INTERNATIONAL SYMPOSIUM ON IT IN MEDICINE AND EDUCATION, VOLS 1 AND 2, PROCEEDINGS, 2008, : 715 - +
  • [10] Impact of CT-MR registration imprecision on treatment planning for prostate cancer
    Elen, A.
    Crijns, W.
    Isebaert, S.
    Haustermans, K.
    Maes, F.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S65 - S65