What Method for Management of Unilateral Mandibular Angle Fractures Has the Lowest Rate of Postoperative Complications? A Systematic Review and Meta-Analysis

被引:63
作者
Al-Moraissi, Essam Ahmed [1 ,2 ]
Ellis, Edward, III [3 ]
机构
[1] Cairo Univ, Fac Oral & Dent Med, Dept Oral & Maxillofacial Surg, Cairo, Egypt
[2] Thamar Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Thamar, Yemen
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Oral & Maxillofacial Surg, San Antonio, TX 78229 USA
关键词
INTERNAL-FIXATION; MINIPLATE FIXATION; OPEN REDUCTION; STRUT; PLATE;
D O I
10.1016/j.joms.2014.05.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present study was to determine which method for internal fixation through a transoral approach has the lowest complication rate for patients with mandibular angle fractures (MAFs). Materials and Methods: To address our study purpose, we designed and implemented a systematic review with meta-analysis. To identify the studies to include in the review, a comprehensive electronic search without date or language restrictions was performed in April 2014. The inclusion criteria were studies of humans, including randomized or quasi-randomized controlled trials (RCTs), controlled clinical trials (CCTs), and retrospective studies, with the aim of comparing fixation techniques (1 vs 2 miniplates, external oblique ridge vs lateral border miniplate placement, and geometric vs conventional miniplate) in the management of MAFs. The incidence of postoperative complications was analyzed. Only those studies in which a transoral approach had been used (with or without transbuccal instrumentation) were selected. Results: A total of 20 publications were included: 9 RCTs, 3 CCTs, and 8 retrospective studies. Eight studies had a low risk of bias, 11 studies a moderate risk of bias, and 1 a high risk of bias. A statistically significant difference was found between a single superior border miniplate and the use of 2 miniplates. The cumulative odds ratio (OR) was 0.63, indicating that the use of 1 miniplate in MAF fixation decreased the risk of postoperative complications by 37% compared with using 2 miniplates. Comparing a miniplate placed on the external oblique ridge to one placed on the lateral surface of the mandible resulted in a cumulative OR of 2.10, indicating that the use of the transbuccal miniplate decreased the risk of postoperative complications by 110% compared with a miniplate placed on the external oblique ridge. Comparing geometric and standard miniplates, the OR was 0.29, indicating that the use of a geometric miniplate decreased the risk of postoperative complications by 71% compared with using conventional miniplates. Conclusions: The results of the meta-analysis have shown that the use of 1 miniplate is superior to using 2 in reducing the incidence of postoperative complications in the management of MAFs. In addition, our results showed that the transbuccally placed lateral miniplate was better at reducing the incidence of postoperative complications than one placed on the external oblique ridge using a transoral approach. Finally, geometric miniplates performed better than conventional miniplates in reducing postoperative complications. (C) 2014 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:2197 / 2211
页数:15
相关论文
共 49 条
[1]   Three-dimensional versus standard miniplate fixation in the management of mandibular angle fractures: a systematic review and meta-analysis [J].
Al-Moraissi, E. A. ;
El-Sharkawy, T. M. ;
El-Ghareeb, T. I. ;
Chrcanovic, B. R. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (06) :708-716
[2]  
[Anonymous], COCHRANE HDB SYSTEMA
[3]  
[Anonymous], J MAXILLOFAC ORAL SU
[4]   Superior border plating technique in the management of isolated mandibular angle fractures: A retrospective study of 50 consecutive patients [J].
Barry, Conor P. ;
Kearns, Gerard J. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (08) :1544-1549
[5]   Management of Mandibular Angle Fracture [J].
Braasch, Daniel Cameron ;
Abubaker, A. Omar .
ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2013, 25 (04) :591-+
[6]   MANDIBULAR OSTEOSYNTHESIS BY MINIATURE SCREWED PLATES VIA A BUCCAL APPROACH [J].
CHAMPY, M ;
LODDE, JP ;
SCHMITT, R ;
JAEGER, JH ;
MUSTER, D .
JOURNAL OF MAXILLOFACIAL SURGERY, 1978, 6 (01) :14-21
[7]   CLINICAL AND IN-VITRO EVALUATION OF MANDIBULAR ANGLE FRACTURE FIXATION WITH THE 2-MINIPLATE SYSTEM [J].
CHOI, BH ;
KIM, KN ;
KANG, HS ;
DO, KW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (06) :692-695
[8]   STABILITY TESTING OF A 2-MINIPLATE FIXATION TECHNIQUE FOR MANDIBULAR ANGLE FRACTURES - AN IN-VITRO STUDY [J].
CHOI, BH ;
YOO, JH ;
KIM, KN ;
KANG, HS .
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (02) :122-125
[9]   Management of Bilateral Mandibular Angle Fractures With Combined Rigid and Nonrigid Fixation [J].
Cillo, Joseph E., Jr. ;
Ellis, Edward, III .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (01) :106-111
[10]   Comparison of a Single Noncompression Miniplate Versus 2 Noncompression Miniplates in the Treatment of Mandibular Angle Fractures: A Prospective, Randomized Clinical Trial [J].
Danda, Anil Kumar .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (07) :1565-1567