Determination of trace metal ions in seawater by atomic absorption spectrometry after separation/preconcentration with calmagite on amberlite XAD-1180

被引:40
作者
Soylak, M [1 ]
Saracoglu, S
Elci, L
Dogan, M
机构
[1] Erciyes Univ, Dept Chem, Fac Art & Sci, TR-38039 Kayseri, Turkey
[2] Pamukkale Univ, Fac Art & Sci, Dept Chem, TR-20020 Denizli, Turkey
[3] Hacettepe Univ, Dept Chem, Fac Sci, TR-06532 Ankara, Turkey
关键词
amberlite XAD-1180; column; preconcentration; separation; Cu(II); Ni(II); Pb(II); seawater;
D O I
10.1080/03067310290027794
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A preconcentration/separation method for the atomic absorption spectrometric determinations of Cu(II), Ni(II) and Pb(II) ions in seawater have been established by using a chromatographic column filled Amberlite XAD-1180. The recoveries of Cu(II), Ni(II) and Pb(II) ions were quantitative (>95%) at pH 8-9. The influences of the various analytical parameters including the amount of calmagite, amount of Amberlite XAD-1180, eluent type, etc. were investigated. The influence of the seawater matrix was also examined. Simultaneous enrichment and determination of copper, nickel and lead ions in seawater are possible with satisfactory results (recoveries > 95%, RSD < 9%).
引用
收藏
页码:225 / 231
页数:7
相关论文
共 32 条
[1]  
Acevedo HA, 2001, CHEM ANAL-WARSAW, V46, P59
[2]   On-line preconcentration with different solid adsorbents for lead determination [J].
da Silva, JBB ;
Quináia, SP ;
Rollemberg, MCE .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :657-660
[3]  
DALI CJ, 2000, J CHINESE RARE EARTH, V18, P265
[4]   Enrichment method for trace amounts of rare earth elements using chemofiltration and XRF determination [J].
De Vito, IE ;
Olsina, RA ;
Masi, AN .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :392-396
[5]  
DJANE NK, 1997, THESIS LUND U SWEDEN
[6]   Determination of trace impurities in some nickel compounds by flame atomic absorption spectrometry after solid phase extraction using Amberlite XAD-16 resin [J].
Elçi, L ;
Soylak, M ;
Uzun, A ;
Büyükpatir, E ;
Dogan, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :358-361
[7]   Flow injection solid phase extraction with Chromosorb 102:: determination of lead in soil and waters by flame atomic absorption spectrometry [J].
Elçi, L ;
Arslan, Z ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1109-1116
[8]   Comparison of metal pre-concentration on immobilized Kelex-100 and quadruple inductively coupled plasma mass spectrometric detection with direct double focusing inductively coupled plasma mass spectrometric measurements for ultratrace multi-element determinations in sea-water [J].
Ferrarello, CN ;
Bayón, MM ;
Alonso, JIG ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2001, 429 (02) :227-235
[9]   Copper determination in natural water samples by using FAAS after preconcentration onto amberlite XAD-2 loaded with calmagite [J].
Ferreira, SLC ;
Ferreira, JR ;
Dantas, AF ;
Lemos, VA ;
Araújo, NML ;
Costa, ACS .
TALANTA, 2000, 50 (06) :1253-1259
[10]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264