Automatic contour propagation in cine cardiac magnetic resonance images

被引:69
作者
Hautvast, Gilion [1 ]
Lobregt, Steven
Breeuwer, Marcel
Gerritsen, Frans
机构
[1] Philips Med Syst Healthcare Informat, Adv Dev Dept, NL-5680 DA Best, Netherlands
[2] Tech Univ Eindhoven, Biomed Image Anal Grp, NL-5600 MB Eindhoven, Netherlands
关键词
active contours; cardiac magnetic resonance imaging (MRI); propagation;
D O I
10.1109/TMI.2006.882124
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a method for automatic contour propagation in cine cardiac magnetic resonance images. The method consists of a new active contour model that tries to maintain a constant contour environment by matching gray values in profiles perpendicular to the contour. Consequently, the contours should maintain a constant position with respect to neighboring anatomical structures, such that the resulting contours reflect the preferences of the user. This is particularly important in cine cardiac magnetic resonance images because local image features do not describe the desired contours near the papillary muscle. The accuracy of the propagation result is influenced by several parameters. Because the optimal setting of these parameters is application dependent, we describe how to use full factorial experiments to optimize the parameter setting. We have applied our method to cine cardiac magnetic resonance image sequences from the long axis two-chamber view, the long axis four-chamber view, and the short axis view. We performed our optimization procedure for each contour in each view. Next, we performed an extensive clinical validation of our method on 69 short axis data sets and 38 long axis data sets. In the optimal parameter setting, our propagation method proved to be fast, robust, and accurate. The resulting cardiac contours are positioned within the interobserver ranges of manual segmentation. Consequently, the resulting contours can be used to accurately determine physiological parameters such as stroke volume and ejection fraction.
引用
收藏
页码:1472 / 1482
页数:11
相关论文
共 39 条
[1]   IMAGE SELECTIVE SMOOTHING AND EDGE-DETECTION BY NONLINEAR DIFFUSION .2. [J].
ALVAREZ, L ;
LIONS, PL ;
MOREL, JM .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1992, 29 (03) :845-866
[2]  
AYACHE N, 1992, ACTIVE VISION, P285
[3]  
Blake A., 1992, ACTIVE VISION
[4]   A GEOMETRIC MODEL FOR ACTIVE CONTOURS IN IMAGE-PROCESSING [J].
CASELLES, V ;
CATTE, F ;
COLL, T ;
DIBOS, F .
NUMERISCHE MATHEMATIK, 1993, 66 (01) :1-31
[5]   A methodology for evaluation of boundary detection algorithms on medical images [J].
Chalana, V ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :642-652
[6]   Robust real-time myocardial border tracking for echocardiography: An information fusion approach [J].
Comaniciu, D ;
Zhou, XS ;
Krishnan, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (07) :849-860
[7]  
COOTES T, LECT NOTES COMPUTER, P484
[8]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[9]   Three-dimensional modeling for functional analysis of cardiac images: A review [J].
Frangi, AF ;
Niessen, WJ ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :2-25
[10]   Active contours for tracking distributions [J].
Freedman, D ;
Zhang, T .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (04) :518-526