Transcatheter Aortic Valve-in-Valve Treatment of Degenerative Stentless Supra-annular Freedom Solo Valves: A Single Centre Experience

被引:10
|
作者
Cockburn, James [1 ]
Dooley, Maureen [1 ]
Parker, Jessica [1 ]
Hill, Andrew [1 ]
Hutchinson, Nevil [1 ]
de Belder, Adam [1 ]
Trivedi, Uday [1 ]
Hildick-Smith, David [1 ]
机构
[1] Brighton & Sussex Univ Hosp, Sussex Cardiac Ctr, Brighton BN2 5BE, E Sussex, England
关键词
valve in valve; TAVI; freedom solo; BIOPROSTHETIC SURGICAL VALVES; IMPLANTATION; REPLACEMENT; DURABILITY;
D O I
10.1002/ccd.26623
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Methods: Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2), one had severe regurgitation (AR). Median time to failure was 7 years. Results: Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n=3), and Lotus 23 mm (n=1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. Conclusions: ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1: 1 sizing) should be used, and strategies to protect the coronary vessels must be considered. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 50 条
  • [31] Clinical Experience With the Freedom SOLO Stentless Aortic Valve in 277 Consecutive Patients
    Thalmann, Markus
    Kaiblinger, Josef
    Krausler, Richard
    Pisarik, Harald
    Veit, Franz
    Taheri, Niuscha
    Kornigg, Karin
    Dinges, Christian
    Grabenwoeger, Martin
    Stanger, Olaf
    ANNALS OF THORACIC SURGERY, 2014, 98 (04) : 1301 - 1307
  • [32] Update on supra-annular sizing of transcatheter aortic valve prostheses in raphe-type bicuspid aortic valve disease according to the LIRA method
    Iannopollo, Gianmarco
    Romano, Vittorio
    Esposito, Antonio
    Guazzoni, Giulia
    Ancona, Marco
    Ferri, Luca
    Russo, Filippo
    Bellini, Barbara
    Buzzatti, Nicola
    Curio, Jonathan
    Prendergast, Bernard
    Montorfano, Matteo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24 (SUPPL C) : C233 - C242
  • [33] Transcatheter Aortic Valve Implantation for Bioprosthetic Valve Failure: Placement of Aortic Transcatheter Valves 3 Aortic Valve-in-Valve Study
    Malaisrie, S. Chris
    Zajarias, Alan
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    Hahn, Rebecca T.
    Brown, David
    Wong, S. Chiu
    Oldemeyer, J. Bradley
    Shang, Kan
    Leipsic, Jonathon
    Blanke, Philipp
    Guerrero, Mayra
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (06):
  • [34] Transcatheter Valve-in-Valve Replacement With Balloon- Versus Self-Expanding Valves in Patients With Degenerated Stentless Aortic Bioprosthesis
    Moubarak, Ghadi
    Salih, Mohammed
    Eisenga, John
    McCullough, Kyle
    Ramos, Osniel Gonzalez
    Banwait, Jasjit
    Al-Azizi, Karim
    Mack, Michael J.
    DiMaio, J. Michael
    Szerlip, Molly I.
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 230 : 50 - 57
  • [35] Transfemoral Transcatheter Aortic Valve-in-Valve Implantation for Aortic Valve Bioprosthesis Failure With the Fully Repositionable and Retrievable Lotus Valve: A Single-Center Experience
    Ruparelia, Neil
    Thomas, Katharine
    Newton, James D.
    Grebenik, Kate
    Keiralla, Amar
    Krasopoulos, George
    Sayeed, Rana
    Banning, Adrian P.
    Kharbanda, Rajesh K.
    JOURNAL OF INVASIVE CARDIOLOGY, 2017, 29 (09) : 315 - 319
  • [36] Double Valve-in-Valve Transcatheter Valve Replacements for Failed Surgical Bioprosthetic Aortic and Tricuspid Valves
    Lee, Kyongjune B.
    Trachiotis, Gregory D.
    Reiner, Jonathan S.
    Nagy, Christian D.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (03) : 276 - 280
  • [37] Systematic review and meta-analysis of valve-in-valve transcatheter aortic valve replacement in patients with failed bioprosthetic aortic valves
    Mahmoud, Ahmed N.
    Gad, Mohamed M.
    Elgendy, Islam Y.
    Mahmoud, Ahmad A.
    Taha, Yasmeen
    Elgendy, Akram Y.
    Ahuja, Keerat R.
    Saad, Anas M.
    Simonato, Matheus
    McCabe, James M.
    Reisman, Mark
    Kapadia, Samir R.
    Dvir, Danny
    EUROINTERVENTION, 2020, 16 (07) : 539 - +
  • [38] Redo surgery or valve-in-valve TAVR? Treatment of degenerated bioprosthetic aortic valves
    Demal, Till Joscha
    Westermann, Dirk
    Reichenspurner, Hermann
    Conradi, Lenard
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2022, 36 (03): : 184 - 192
  • [39] VARC-3 defined outcome of valve-in-valve transcatheter aortic valve implantation in stentless compared with stented aortic bioprostheses
    Steul, Jean-Honore
    Abdel-Wahab, Mohamed
    Stankowski, Tomasz
    Haussig, Stephan
    Woitek, Felix J.
    Gasior, Tomasz
    Crusius, Lisa
    Knorr, Luise
    Mueller, Felicitas V.
    Fritzsche, Dirk
    Kiefer, Philipp
    Kappert, Utz
    Holzhey, David
    Linke, Axel
    Mangner, Norman
    CLINICAL RESEARCH IN CARDIOLOGY, 2025, 114 (03) : 291 - 301
  • [40] Transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic and mitral valves
    Gallo, Michele
    Dvir, Danny
    Demertzis, Stefanos
    Pedrazzini, Giovanni
    Berdajs, Denis
    Ferrari, Enrico
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (08) : 749 - 758