Transcatheter Aortic Valve-in-Valve Treatment of Degenerative Stentless Supra-annular Freedom Solo Valves: A Single Centre Experience

被引:10
|
作者
Cockburn, James [1 ]
Dooley, Maureen [1 ]
Parker, Jessica [1 ]
Hill, Andrew [1 ]
Hutchinson, Nevil [1 ]
de Belder, Adam [1 ]
Trivedi, Uday [1 ]
Hildick-Smith, David [1 ]
机构
[1] Brighton & Sussex Univ Hosp, Sussex Cardiac Ctr, Brighton BN2 5BE, E Sussex, England
关键词
valve in valve; TAVI; freedom solo; BIOPROSTHETIC SURGICAL VALVES; IMPLANTATION; REPLACEMENT; DURABILITY;
D O I
10.1002/ccd.26623
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Methods: Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2), one had severe regurgitation (AR). Median time to failure was 7 years. Results: Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n=3), and Lotus 23 mm (n=1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. Conclusions: ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1: 1 sizing) should be used, and strategies to protect the coronary vessels must be considered. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 50 条
  • [1] Supra-Annular Self-Expanding Versus Balloon-Expandable Valves for Valve-in-Valve Transcatheter Aortic Valve Replacement
    Ahmad, Danial
    Sa, Michel Pompeu
    Yousef, Sarah
    Brown, James A.
    Doshi, Nandini
    Kliner, Dustin E.
    Serna-Gallegos, Derek
    Wang, Yisi
    Thoma, Floyd
    Toma, Catalin
    Makani, Amber
    Hasan, Irsa
    West, Dave
    Sultan, Ibrahim
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 231 : 55 - 61
  • [2] Transcatheter aortic valve implantation for degenerated aortic valves: Experience with a new supra-annular device. The Spanish Allegra valve-in-valve (SAVIV) registry
    Moreno, Raul
    Baz, Jose-Antonio
    Moreu, Jose
    Berenguer, Alberto
    Gonzalvez-Garcia, Ariana
    Galeote, Guillermo
    Hernandez, Ubaldo
    Canton, Tomas
    Jimenez-Valero, Santiago
    Jurado-Roman, Alfonso
    Moya, Halley
    Lazaro, Esther
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (02) : 365 - 370
  • [3] Valve-in-valve transcatheter aortic valve implantation for failing surgical aortic stentless bioprosthetic valves: A single-center experience
    Duncan, Alison
    Davies, Simon
    Di Mario, Carlo
    Moat, Neil
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (01) : 91 - 98
  • [4] Transcatheter aortic valve-in-valve treatment in prior Sorin Freedom Solo valve
    Rahman, Mohammed Shamim
    Cockburn, James
    Trivedi, Uday
    Hildick-Smith, David
    EUROINTERVENTION, 2018, 14 (03) : 280 - 281
  • [5] Incidence of Prosthesis-Patient Mismatch in Valve-in-Valve with a Supra-Annular Valve
    Alwan, Louhai
    Ruge, Hendrik
    Krane, Markus
    Prinzing, Anatol
    Noebauer, Christian
    Lange, Rudiger
    Erlebach, Magdalena
    THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (08) : 632 - 640
  • [6] Initial experience with the Freedom Solo® stentless aortic valve in a low volume centre
    Kolseth, Solveig Moss
    Nordhaug, Dag
    Stenseth, Roar
    Wahba, Alexander
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2010, 44 (05) : 301 - 306
  • [7] Annular versus supra-annular sizing for transcatheter aortic valve replacement in bicuspid aortic valve disease
    Weir-McCall, Jonathan R.
    Attinger-Toller, Adrian
    Blanke, Philipp
    Perlman, Gidon Y.
    Sellers, Stephanie L.
    Wood, David
    Webb, John G.
    Leipsic, Jonathon
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (05) : 407 - 413
  • [8] Transcatheter Aortic Valve-in-Valve Implantation for Patients With Degenerative Surgical Bioprosthetic Valves
    Dvir, Danny
    Barbanti, Marco
    Tan, John
    Webb, John G.
    CURRENT PROBLEMS IN CARDIOLOGY, 2014, 39 (01) : 7 - 27
  • [9] Transcatheter Aortic Valve-in-Valve Implantation for Patients With Degenerative Surgical Bioprosthetic Valves
    Dvir, Danny
    Webb, John G.
    CIRCULATION JOURNAL, 2015, 79 (04) : 695 - 703
  • [10] Supra-annular sizing for transcatheter valve implantation in bicuspid aortic stenosis
    Jeger, Raban
    Reuthebuch, Oliver
    Fahrni, Gregor
    Laborde, Jean-Claude
    Vogel, Rolf
    Kaiser, Christoph
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (02): : 187 - 190