Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients

被引:0
|
作者
Travade, A
Isnard, A
Bagard, C
Bouchet, F
Chouzet, S
Gaillot, A
Vilmant, R
机构
[1] Ctr Republ, Ctr Senol, F-63100 Clermont Ferrand, France
[2] Ctr Republ, Anat Pathol Lab, F-63100 Clermont Ferrand, France
来源
JOURNAL DE RADIOLOGIE | 2002年 / 83卷 / 09期
关键词
breast; breast neoplasms; diagnosis; breast biopsy; mammotome; breast calcifications; specimen radiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of percutaneous vacuum-assisted core biopsy to improve the diagnosis of non palpable mammographic abnormalities. Materials and methods: A total of 252 core biopsies using an 11G Mammotome(R) were performed in 249 patients. Stereotactic localization was performed in the prone position on a dedicated digital Fischer table. Results: Fifty-one, or 25%, of 200 clusters of microcalcifications corresponded to carcinomas: 126 benign lesions, 23 atypical hyperplasia and LCIS, 31 DCIS, 15 invasive ductal carcinomas, and 4 false negative biopsies. In these 4 last cases, surgery was performed because radiographs of the core biopsy showed no microcalcifications; carcinoma was confirmed at histology of the surgical specimen. Using the BI-RADS system, 7 lesions were category 3, 175 lesions were category 4, and 18 lesions were category 5. From a total of 52 masses, 31 were benign lesions, 2 were borderline lesions, and 19 were invasive carcinomas. From these, 5 lesions were category 3, 31 were category 4, and 16 were category 5. Diagnostic surgical biopsy was avoided in 161 cases (63%), in 152 cases for benign lesions including 151 lesions classified as category 4 lesions and in 9 cases for multifocal or recurrent malignant lesions. Conclusion: When technical pitfalls are avoided and when presence of microcalcifications in the core biopsy sample is verified, vacuum assisted core biopsy with Mammotome(R) 11G provides accurate diagnosis of non-palpable mammographic abnormalities.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 50 条
  • [31] Atypical ductal hyperplasia: Can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision?
    Jackman, RJ
    Birdwell, RL
    Ikeda, DM
    RADIOLOGY, 2002, 224 (02) : 548 - 554
  • [32] Stereotactic vacuum-assisted breast biopsy: Comparison between 11-and 8-gauge needles
    Ruggirello, Irene
    Nori, Jacopo
    Desideri, Isacco
    Saieva, Calogero
    Giannotti, Elisabetta
    Bicchierai, Giulia
    De Benedetto, Diego
    Francolini, Giulio
    Bianchi, Simonetta
    Vezzosi, Vania
    Sanchez, Luis
    Susini, Tommaso
    Orzalesi, Lorenzo
    Meattini, Icro
    Livi, Lorenzo
    Miele, Vittorio
    EJSO, 2017, 43 (12): : 2257 - 2260
  • [33] Stereotactic vacuum-assisted breast biopsy: our experience and comparison with stereotactic automated needle biopsy
    Tothova, L.
    Rauova, K.
    Valkovic, L.
    Vanovcanova, L.
    Lehotska, V
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2013, 114 (02): : 71 - 77
  • [34] Stereotactic 9-gauge vacuum-assisted breast biopsy, how many specimens are needed?
    den Dekker, Bianca M.
    van Diest, Paul J.
    de Waard, Stephanie N.
    Verkooijen, Helena M.
    Pijnappel, Ruud M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [35] Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions
    Tonegutti M.
    Girardi V.
    La radiologia medica, 2008, 113 (1) : 65 - 75
  • [36] Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions
    Tonegutti, M.
    Girardi, V.
    RADIOLOGIA MEDICA, 2008, 113 (01): : 65 - 75
  • [37] Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    Burbank, F
    RADIOLOGY, 1997, 202 (03) : 843 - 847
  • [38] Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies
    Burbank, F
    RADIOLOGY, 1997, 204 (01) : 153 - 156
  • [39] The Efficacy of Stereotactic Vacuum-assisted Biopsy and Needle Localization Vacuum-assisted Biopsy for Diagnosing Breast Microcalcification
    Lee, Eung-Jik
    Oh, Se-Min
    JOURNAL OF BREAST CANCER, 2010, 13 (01) : 53 - 58
  • [40] Stereotactic vacuum-assisted breast biopsy in 2874 patients -: A Multicenter study
    Kettritz, U
    Rotter, K
    Schreer, I
    Murauer, M
    Schulz-Wendtiand, R
    Peter, D
    Heywang-Köbrunner, SH
    CANCER, 2004, 100 (02) : 245 - 251