Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients

被引:0
|
作者
Travade, A
Isnard, A
Bagard, C
Bouchet, F
Chouzet, S
Gaillot, A
Vilmant, R
机构
[1] Ctr Republ, Ctr Senol, F-63100 Clermont Ferrand, France
[2] Ctr Republ, Anat Pathol Lab, F-63100 Clermont Ferrand, France
来源
JOURNAL DE RADIOLOGIE | 2002年 / 83卷 / 09期
关键词
breast; breast neoplasms; diagnosis; breast biopsy; mammotome; breast calcifications; specimen radiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of percutaneous vacuum-assisted core biopsy to improve the diagnosis of non palpable mammographic abnormalities. Materials and methods: A total of 252 core biopsies using an 11G Mammotome(R) were performed in 249 patients. Stereotactic localization was performed in the prone position on a dedicated digital Fischer table. Results: Fifty-one, or 25%, of 200 clusters of microcalcifications corresponded to carcinomas: 126 benign lesions, 23 atypical hyperplasia and LCIS, 31 DCIS, 15 invasive ductal carcinomas, and 4 false negative biopsies. In these 4 last cases, surgery was performed because radiographs of the core biopsy showed no microcalcifications; carcinoma was confirmed at histology of the surgical specimen. Using the BI-RADS system, 7 lesions were category 3, 175 lesions were category 4, and 18 lesions were category 5. From a total of 52 masses, 31 were benign lesions, 2 were borderline lesions, and 19 were invasive carcinomas. From these, 5 lesions were category 3, 31 were category 4, and 16 were category 5. Diagnostic surgical biopsy was avoided in 161 cases (63%), in 152 cases for benign lesions including 151 lesions classified as category 4 lesions and in 9 cases for multifocal or recurrent malignant lesions. Conclusion: When technical pitfalls are avoided and when presence of microcalcifications in the core biopsy sample is verified, vacuum assisted core biopsy with Mammotome(R) 11G provides accurate diagnosis of non-palpable mammographic abnormalities.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 50 条
  • [21] Tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: methodological issue on validity and reliability
    Siamak Sabour
    Breast Cancer, 2017, 24 : 730 - 731
  • [22] Clip or marker migration 5-10 weeks after stereotactic 11-gauge vacuum-assisted breast biopsy: Report of two cases
    Birdwell, RL
    Jackman, RJ
    RADIOLOGY, 2003, 229 (02) : 541 - 544
  • [23] Value of stereotactic 11-gauge vacuum-assisted breast biopsy in non-palpable suspicious calcifications: an eight-year single institution experience with 587 patients
    Li, Shiping
    Qu, Feilin
    Yang, Yinlong
    Wang, Lei
    Shen, Juping
    Shao, Zhiming
    GLAND SURGERY, 2020, 9 (05) : 1258 - +
  • [24] Stereotactic breast biopsy of noncalcified lesions - A cost-minimization analysis comparing 14-gauge multipass automated core biopsy to 14-and 11-gauge vacuum-assisted biopsy
    Soo, MS
    Kliewer, MA
    Ghate, S
    Helsper, RS
    Rosen, EL
    CLINICAL IMAGING, 2005, 29 (01) : 26 - 33
  • [25] Frequency and Upgrade Rates of Atypical Ductal Hyperplasia Diagnosed at Stereotactic Vacuum-Assisted Breast Biopsy: 9-Versus 11-Gauge
    Eby, Peter R.
    Ochsner, Jennifer E.
    DeMartini, Wendy B.
    Allison, Kimberly H.
    Peacock, Sue
    Lehman, Constance D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (01) : 229 - 234
  • [26] Nonpalpable breast cancer: Percutaneous diagnosis with 11-and 8-gauge stereotactic vacuum-assisted biopsy devices
    Brem, RF
    Schoonjans, JM
    Goodman, SN
    Nolten, A
    Askin, FB
    Gatewood, OMB
    RADIOLOGY, 2001, 219 (03) : 793 - 796
  • [27] A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system
    Fine, RE
    Israel, PZ
    Walker, LC
    Corgan, KR
    Greenwald, LV
    Berenson, JE
    Boyd, BA
    Oliver, MK
    McClure, T
    Elberfeld, J
    AMERICAN JOURNAL OF SURGERY, 2001, 182 (04) : 335 - 340
  • [28] UNDERESTIMATION OF ATYPICAL LOBULAR HYPERPLASIA AND LOBULAR CARCINOMA IN SITU AT STEREOTAXIC 11-GAUGE VACUUM-ASSISTED BREAST BIOPSY
    Gatta, G.
    Di Grezia, G.
    Ancona, A.
    Capodieci, M.
    Coppolino, F.
    Rossi, C.
    Feragalli, B.
    Iacomino, A.
    Cappabianca, S.
    Grassi, R.
    EUROPEAN JOURNAL OF INFLAMMATION, 2013, 11 (03) : 825 - 835
  • [29] Stereotactic directional vacuum-assisted breast biopsy using lateral approach
    Nakamura, Yuko
    Urashima, Masaki
    Matsuura, Akiko
    Nishihara, Reisuke
    Itoh, Atsushi
    Kagemoto, Masayuki
    Higaki, Kenji
    BREAST CANCER, 2010, 17 (04) : 286 - 289
  • [30] Clip placement after stereotactic vacuum-assisted breast biopsy
    Liberman, L
    Dershaw, DD
    Morris, EA
    Abramson, AF
    Thornton, CM
    Rosen, PP
    RADIOLOGY, 1997, 205 (02) : 417 - 422