Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients

被引:0
作者
Travade, A
Isnard, A
Bagard, C
Bouchet, F
Chouzet, S
Gaillot, A
Vilmant, R
机构
[1] Ctr Republ, Ctr Senol, F-63100 Clermont Ferrand, France
[2] Ctr Republ, Anat Pathol Lab, F-63100 Clermont Ferrand, France
来源
JOURNAL DE RADIOLOGIE | 2002年 / 83卷 / 09期
关键词
breast; breast neoplasms; diagnosis; breast biopsy; mammotome; breast calcifications; specimen radiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of percutaneous vacuum-assisted core biopsy to improve the diagnosis of non palpable mammographic abnormalities. Materials and methods: A total of 252 core biopsies using an 11G Mammotome(R) were performed in 249 patients. Stereotactic localization was performed in the prone position on a dedicated digital Fischer table. Results: Fifty-one, or 25%, of 200 clusters of microcalcifications corresponded to carcinomas: 126 benign lesions, 23 atypical hyperplasia and LCIS, 31 DCIS, 15 invasive ductal carcinomas, and 4 false negative biopsies. In these 4 last cases, surgery was performed because radiographs of the core biopsy showed no microcalcifications; carcinoma was confirmed at histology of the surgical specimen. Using the BI-RADS system, 7 lesions were category 3, 175 lesions were category 4, and 18 lesions were category 5. From a total of 52 masses, 31 were benign lesions, 2 were borderline lesions, and 19 were invasive carcinomas. From these, 5 lesions were category 3, 31 were category 4, and 16 were category 5. Diagnostic surgical biopsy was avoided in 161 cases (63%), in 152 cases for benign lesions including 151 lesions classified as category 4 lesions and in 9 cases for multifocal or recurrent malignant lesions. Conclusion: When technical pitfalls are avoided and when presence of microcalcifications in the core biopsy sample is verified, vacuum assisted core biopsy with Mammotome(R) 11G provides accurate diagnosis of non-palpable mammographic abnormalities.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 50 条
[1]   Is surgical excision necessary for atypical ductal hyperplasia of the breast diagnosed by mammotome? [J].
Adrales, G ;
Turk, P ;
Wallace, T ;
Bird, R ;
Norton, HJ ;
Greene, F .
AMERICAN JOURNAL OF SURGERY, 2000, 180 (04) :313-315
[2]  
[Anonymous], BREAST IM REP DAT SY
[3]   Breast imaging reporting and data system standardized mammography lexicon: Observer variability in lesion description [J].
Baker, JA ;
Kornguth, PJ ;
Floyd, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :773-778
[4]  
Beck R M, 2000, Swiss Surg, V6, P108, DOI 10.1024/1023-9332.6.3.108
[5]   Atypical ductal hyperplasia: Histologic underestimation of carcinoma in tissue harvested from impalpable breast lesions using 11-gauge stereotactically guided directional vacuum-assisted biopsy [J].
Brem, RF ;
Behrndt, VS ;
Sanow, L ;
Gatewood, OMB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) :1405-1407
[6]   Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies [J].
Burbank, F .
RADIOLOGY, 1997, 204 (01) :153-156
[7]  
Burbank F, 1996, AM SURGEON, V62, P738
[8]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[9]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[10]  
Cangiarella J, 2001, CANCER-AM CANCER SOC, V91, P173, DOI 10.1002/1097-0142(20010101)91:1<173::AID-CNCR22>3.0.CO