Imaging fascicular organization of rat sciatic nerves with fast neural electrical impedance tomography

被引:30
|
作者
Ravagli, Enrico [1 ]
Mastitskaya, Svetlana [1 ]
Thompson, Nicole [1 ]
Iacoviello, Francesco [2 ]
Shearing, Paul R. [2 ]
Perkins, Justin [3 ]
Gourine, Alexander, V [4 ]
Aristovich, Kirill [1 ]
Holder, David [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London, England
[2] UCL, Dept Chem Engn, Electrochem Innovat Lab, London, England
[3] Royal Vet Coll, Clin Sci & Serv, Hawkshead Lane, Hatfield, Herts, England
[4] UCL, Ctr Cardiovasc & Metab Neurosci, Dept Neurosci Physiol & Pharmacol, London, England
基金
英国医学研究理事会;
关键词
BRAIN; REGULARIZATION; FEASIBILITY; SHRINKAGE; SYSTEM; EIT;
D O I
10.1038/s41467-020-20127-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Imaging compound action potentials (CAPs) in peripheral nerves could help avoid side effects in neuromodulation by selective stimulation of identified fascicles. Existing methods have low resolution, limited imaging depth, or are invasive. Fast neural electrical impedance tomography (EIT) allows fascicular CAP imaging with a resolution of <200<mu>m, <1ms using a non-penetrating flexible nerve cuff electrode array. Here, we validate EIT imaging in rat sciatic nerve by comparison to micro-computed tomography (microCT) and histology with fluorescent dextran tracers. With EIT, there are reproducible localized changes in tissue impedance in response to stimulation of individual fascicles (tibial, peroneal and sural). The reconstructed EIT images correspond to microCT scans and histology, with significant separation between the fascicles (p<0.01). The mean fascicle position is identified with an accuracy of 6% of nerve diameter. This suggests fast neural EIT can reliably image the functional fascicular anatomy of the nerves and so aid selective neuromodulation. To be successful, selective neuromodulation requires a non-invasive method of imaging the fascicular anatomy of peripheral nerves. Here, the authors show the applicability and reliability of fast neural electrical impedance tomography for this purpose and provide its validation against the gold standards of invasive imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Imaging fascicular organization of rat sciatic nerves with fast neural electrical impedance tomography
    Enrico Ravagli
    Svetlana Mastitskaya
    Nicole Thompson
    Francesco Iacoviello
    Paul R. Shearing
    Justin Perkins
    Alexander V. Gourine
    Kirill Aristovich
    David Holder
    Nature Communications, 11
  • [2] Imaging fast neural traffic at fascicular eve with electrical impedance tomography: proof of principle in rat sciatic nerve
    Aristovich, Kirill
    Donega, Matteo
    Blochet, Camille
    Avery, James
    Hannan, Sana
    Chew, Daniel J.
    Holder, David
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (05)
  • [3] Optimization of the electrode drive pattern for imaging fascicular compound action potentials in peripheral nerve with fast neural electrical impedance tomography
    Ravagli, Enrico
    Mastitskaya, Svetlana
    Thompson, Nicole
    Aristovich, Kirill
    Holder, David
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (11)
  • [4] Investigating the safety of fast neural electrical impedance tomography in the rat brain
    Hannan, Sana
    Faulkner, Mayo
    Aristovich, Kirin
    Avery, James
    Holder, David
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (03)
  • [5] Imaging fast electrical activity in the brain with electrical impedance tomography
    Aristovich, Kirill Y.
    Packham, Brett C.
    Koo, Hwan
    dos Santos, Gustavo Sato
    McEvoy, Andy
    Holder, David S.
    NEUROIMAGE, 2016, 124 : 204 - 213
  • [6] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [7] Feasibility study of imaging fast neural activity in retinal tissue using Electrical Impedance Tomography
    Zhu, Danyi
    Fang, Xiunan
    Eiber, Calvin
    Avery, James
    Holder, David
    McEwan, Alistair
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 529 - 532
  • [8] Microelectrode array electrical impedance tomography for fast functional imaging in the thalamus
    Zhu, Danyi
    McEwan, Alistair
    Eiber, Calvin
    NEUROIMAGE, 2019, 198 : 44 - 52
  • [9] Ultrasound imaging of regenerating rat sciatic nerves in situ
    Kuffler, Damien P.
    JOURNAL OF NEUROSCIENCE METHODS, 2010, 188 (02) : 276 - 279
  • [10] Empirical validation of statistical parametric mapping for group imaging of fast neural activity using electrical impedance tomography
    Packham, B.
    Barnes, G.
    dos Santos, G. Sato
    Aristovich, K.
    Gilad, O.
    Ghosh, A.
    Oh, T.
    Holder, D.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (06) : 951 - 967