Sensor-less control of the methanol concentration of direct methanol fuel cells at varying ambient temperatures

被引:12
作者
An, Myung-Gi
Mehmood, Asad
Ha, Heung Yong [1 ]
机构
[1] Korea Inst Sci & Technol, Energy Convergence Res Ctr, Seoul 136791, South Korea
关键词
Direct methanol fuel cell; Sensor-less control; Methanol concentration; Stack temperature; Ambient temperature; PERFORMANCE; MEMBRANE; SYSTEM; IMPROVEMENT;
D O I
10.1016/j.apenergy.2014.04.100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new version of an algorithm is used to control the methanol concentration in the feed of DMFC systems without using methanol sensors under varying ambient temperatures. The methanol concentration is controlled indirectly by controlling the temperature of the DMFC stack, which correlates well with the methanol concentration. Depending on the ambient temperature relative to a preset reference temperature, two different strategies are used to control the stack temperature: either reducing the cooling rate of the methanol solution passing through an anode-side heat exchanger; or, lowering the pumping rate of the pure methanol to the depleted feed solution. The feasibility of the algorithm is evaluated using a DMFC system that consists of a 200 W stack and the balance of plant (BOP). The DMFC system includes a sensor-less methanol controller that is operated using a LabView system as the central processing unit. The algorithm is experimentally confirmed to precisely control the methanol concentration and the stack temperature at target values under an environment of varying ambient temperatures. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 26 条
[1]   Passive direct methanol fuel cells for portable electronic devices [J].
Achmad, F. ;
Kamarudin, S. K. ;
Daud, W. R. W. ;
Majlan, E. H. .
APPLIED ENERGY, 2011, 88 (05) :1681-1689
[2]  
[Anonymous], J MEMBR SCI
[3]  
[Anonymous], APPL ENERGY
[4]  
Aricò AS, 2001, FUEL CELLS, V1, P133
[5]   Regulating methanol feed concentration in direct methanol fuel cells using feedback from voltage measurements [J].
Arisetty, Srikanth ;
Jacob, Cedric A. ;
Prasad, Ajay K. ;
Advani, Suresh G. .
JOURNAL OF POWER SOURCES, 2009, 187 (02) :415-421
[6]   Fuel sensor-less control of a liquid feed fuel cell under dynamic loading conditions for portable power sources (I) [J].
Chang, C. L. ;
Chen, C. Y. ;
Sung, C. C. ;
Liou, D. H. .
JOURNAL OF POWER SOURCES, 2008, 182 (01) :133-140
[7]   Fuel sensor-less control of a liquid feed fuel cell system under steady load for portable applications [J].
Chang, C. L. ;
Chen, C. Y. ;
Sung, C. C. ;
Liou, D. H. .
JOURNAL OF POWER SOURCES, 2007, 164 (02) :606-613
[8]   Fuel sensor-less control of a liquid feed fuel cell under dynamic loading conditions for portable power sources (II) [J].
Chang, C. L. ;
Chen, C. Y. ;
Sung, C. C. ;
Liou, D. H. ;
Chang, C. Y. ;
Cha, H. C. .
JOURNAL OF POWER SOURCES, 2010, 195 (05) :1427-1434
[9]   Portable DMFC system with methanol sensor-less control [J].
Chen, C. Y. ;
Liu, D. H. ;
Huang, C. L. ;
Chang, C. L. .
JOURNAL OF POWER SOURCES, 2007, 167 (02) :442-449
[10]   Operation Characteristic Analysis of a Direct Methanol Fuel Cell System Using the Methanol Sensor-less Control Method [J].
Chen, C. Y. ;
Chang, C. L. ;
Sung, C. C. .
FUEL CELLS, 2012, 12 (05) :883-891