Integrated analytical modeling of transient heat transfer inside and outside U-tube ground heat exchanger: A new angle from composite-medium method

被引:19
作者
Luo, Yongqiang [1 ]
Yan, Tian [1 ]
Yu, Jinghua [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Peoples R China
关键词
Ground heat exchanger; Analytical modeling; Composite medium method; Ground source heat pump; Transient heat transfer; LINE-SOURCE MODEL; THERMAL-RESISTANCE; BOREHOLE; TIME; PERFORMANCE; PILE; SIMULATION; RESPONSES;
D O I
10.1016/j.ijheatmasstransfer.2020.120373
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ground heat exchanger (GHE) is vital to geothermal energy utilization, seasonal energy storage, etc. The transient heat transfer analytical model is still a challenge for U-tube GHE due to the asymmetric structure and complex heat interaction among fluid, grout and soil. This study proposed a novel analytical model for U-tube GHE from a new angle of composite medium method. An inspiration from heat transfer of GHE in multilayer soil helps with the new modeling. Combining with the techniques of treating non-uniform pipe wall temperature/heat flux as well as effect of ground surface flux, a new analytical model of U-tube GHE is established. Both experimental data and other simulation data are used for model verifications. The investigation on the temperature evolution in longitudinal and cross section of GHE is realized through visualization method. The analysis on grout material selection and borehole depth design revealed some new results. The spatial distribution of temperature curve in different grout materials share the same shape in steady state stage. This result can offer a useful guide for quick evaluation of effect grout material. At last, the proper time step and U-tube segmentation is suggested to ensure a fast computation and a better simulation accuracy. This study offered a new paradigm for GHE simulation which may contribute to the system optimization, design and many other types modeling as well. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 49 条
  • [1] Multilayer finite line source model for vertical heat exchangers
    Abdelaziz, Sherif L.
    Ozudogru, Tolga Y.
    Olgun, C. Guney
    Martin, James R., II
    [J]. GEOTHERMICS, 2014, 51 : 406 - 416
  • [2] Analytical and semi-analytical solutions for short-time transient response ground heat exchangers
    Bandyopadhyay, Gopal
    Gosnold, William
    Mann, Michael
    [J]. ENERGY AND BUILDINGS, 2008, 40 (10) : 1816 - 1824
  • [3] Thermal resistance and capacity models for borehole heat exchangers
    Bauer, D.
    Heidemann, W.
    Mueller-Steinhagen, H.
    Diersch, H. -J. G.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (04) : 312 - 320
  • [4] The importance of surface air temperature fluctuations on long-term performance of vertical ground heat exchangers
    Bidarmaghz, Asal
    Narsilio, Guillermo A.
    Johnston, Ian W.
    Colls, Stuart
    [J]. GEOMECHANICS FOR ENERGY AND THE ENVIRONMENT, 2016, 6 : 35 - 44
  • [5] Carslaw HS, 1959, CONDUCTION HEAT SOLI
  • [6] Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system
    Chen, Jinhua
    Xia, Lei
    Li, Baizhan
    Mmereki, Daniel
    [J]. RENEWABLE ENERGY, 2015, 73 : 46 - 54
  • [7] A comprehensive review on 2D and 3D models of vertical ground heat exchangers
    Cui, Yuanlong
    Zhu, Jie
    Twaha, Ssennoga
    Riffat, Saffa
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 94 : 84 - 114
  • [8] Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage
    Dai, L. H.
    Shang, Y.
    Li, X. L.
    Li, S. F.
    [J]. RENEWABLE ENERGY, 2016, 87 : 1121 - 1129
  • [9] De Carli M, 2010, RENEW ENERG, V35, P1537, DOI [10.1016/j.renene.2009.11.034, 10.1016/j.renene2009.11.034]
  • [10] Eskilson P., 1987, THERMAL ANAL HEAT EX