Development of Quantum Dot-Based Lateral Flow Immunoassay System for Rapid Quantitative Detection of Human Chorionic Gonadotropin

被引:1
作者
Yang Qiu-Hua [1 ]
Wang Xin [2 ]
Yang Jiu-Min [3 ]
Li Xue [1 ]
Song Tao [1 ]
Gong Xiao-Qun [1 ]
Zhang Bing-Bo [4 ]
Chang Jin [1 ]
机构
[1] Tianjin Univ, Inst Nanobiotechnol, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
[2] Tianjin Med Univ, Gen Hosp, Tianjin 300052, Peoples R China
[3] Tianjin Med Univ, Sch Basic Med Sci, Tianjin 300070, Peoples R China
[4] Tongji Univ, Inst Adv Mat Nano Biomed, Shanghai 200092, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
quantum dot; lateral flow immunoassay; point-of-care testing; human chorionic gonadotropin; LINKED-IMMUNOSORBENT-ASSAY; AUTOMATED CHEMILUMINESCENCE IMMUNOASSAY; IMMUNOCHROMATOGRAPHIC STRIP TEST; PROSTATE-SPECIFIC ANTIGEN; FLUORESCENCE IMMUNOASSAY; SALMONELLA-TYPHIMURIUM; PHOSPHOR REPORTERS; DRUG-DELIVERY; HUMAN SERUM; PCR ASSAY;
D O I
10.3724/SP.J.1206.2013.00181
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we developed a novel fluorescent biosensor that integrates a lateral flow test strip with quantum dot (QD) and a home-made test strip reader for rapid, low-cost, quantitative, and sensitive human chorionic gonadotropin (HCG) detection. The serum HCG level is a reliable marker for detecting persistent gestational trophoblastic neoplasia (GTN) and reflects the clinical course of the disease. The biosensor is designed to combine the rapidness of lateral flow immunoassay and sensitivity of fluorescent immunoassay. The principle of this biosensor is on the basis of a sandwich immunoreaction that was performed on the test strip and the QDs are captured on the test line through antibody-antigen reaction and on the control line through the immobilized secondary antibody. Quantitative detection is realized by recording the intensity of the test line and control line with our home-made test strip reader. The results are determined by the ratio of the fluorescence intensity of the test line and control line (I-T/I-C), which would cancel out the influence of the stability of QDs and antibody. The immunoreaction time and the sample volume are optimized to get a higher sensitivity. Under optimal conditions, the QD-based lateral flow immunoassay system has a wide dynamic range and is capable of detecting a minimum 0.85 IU/L HCG standard analyte in 15 min with 50 mu l sample volume. The novel QD-based lateral flow immunoassay biosensor offers a rapid, sensitive and quantitative tool for point-of-care testing of the level of serum HCG and shows great promise in other protein markers.
引用
收藏
页码:497 / 507
页数:11
相关论文
共 48 条
  • [1] BEGGS M, 1990, CLIN CHEM, V36, P1084
  • [2] Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples
    Bhattacharyya, A.
    Klapperich, C. M.
    [J]. BIOMEDICAL MICRODEVICES, 2007, 9 (02) : 245 - 251
  • [3] Serum insulin-like growth factor I reference values for an automated chemiluminescence immunoassay system:: Results from a multicenter study
    Brabant, G
    von zur Mühlen, A
    Wüster, C
    Ranke, MB
    Kratzsch, J
    Kiess, W
    Ketelslegers, JM
    Wilhelmsen, L
    Hulthén, L
    Saller, B
    Mattsson, A
    Wilde, J
    Schemer, R
    Kann, P
    [J]. HORMONE RESEARCH, 2003, 60 (02) : 53 - 60
  • [4] Small Upconverting Fluorescent Nanoparticles for Biomedical Applications
    Chatterjee, Dev K.
    Gnanasammandhan, Muthu Kumara
    Zhang, Yong
    [J]. SMALL, 2010, 6 (24) : 2781 - 2795
  • [5] A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I)
    Choi, S
    Choi, EY
    Kim, DJ
    Kim, JH
    Kim, TS
    Oh, SW
    [J]. CLINICA CHIMICA ACTA, 2004, 339 (1-2) : 147 - 156
  • [6] Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum
    Corstjens, Paul L. A. M.
    van Lieshout, Lisette
    Zuiderwijk, Michel
    Kornelis, Dieuwke
    Tanke, Hans J.
    Deelder, Andre M.
    van Dam, Govert J.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) : 171 - 176
  • [7] Lateral-flow and up-converting phosphor reporters to detect single-stranded nucleic acids in a sandwich-hybridization assay
    Corstjens, PLAM
    Zuiderwijk, M
    Nilsson, M
    Feindt, H
    Niedbala, RS
    Tanke, HJ
    [J]. ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) : 191 - 200
  • [8] In vivo cancer targeting and imaging with semiconductor quantum dots
    Gao, XH
    Cui, YY
    Levenson, RM
    Chung, LWK
    Nie, SM
    [J]. NATURE BIOTECHNOLOGY, 2004, 22 (08) : 969 - 976
  • [9] One step immunochromatographic assay for the rapid detection of Alexandrium minutum
    Gas, Fabienne
    Baus, Beatrice
    Pinto, Laetitia
    Compere, Chantal
    Tanchou, Valerie
    Quemeneur, Eric
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (05) : 1235 - 1239
  • [10] Multi-wavelength microflow cytometer using groove-generated sheath flow
    Golden, Joel P.
    Kim, Jason S.
    Erickson, Jeffrey S.
    Hilliard, Lisa R.
    Howell, Peter B.
    Anderson, George P.
    Nasir, Mansoor
    Ligler, Frances S.
    [J]. LAB ON A CHIP, 2009, 9 (13) : 1942 - 1950