Model-Based Estimation of Cardiac Output and Total Peripheral Resistance

被引:19
|
作者
Parlikar, T. A. [1 ]
Heldt, T. [1 ]
Ranade, G. V. [1 ]
Verghese, G. C. [1 ]
机构
[1] MIT, Cambridge, MA 02139 USA
来源
COMPUTERS IN CARDIOLOGY 2007, VOL 34 | 2007年 / 34卷
关键词
D O I
10.1109/CIC.2007.4745501
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We describe a novel model-based approach to estimate cardiac output (CO) and total peripheral resistance (TPR) continuously from peripheral arterial blood pressure (ABP) waveforms. Our method exploits the intra-beat and inter-beat variability in ABP to estimate the lumped time constant of a beat-to-beat averaged Windkessel model of the arterial tree, from which we obtain an uncalibrated estimate of CO. To estimate absolute CO, we determine the lumped arterial compliance using calibration data, and assuming either constant or state-dependent compliance. We applied our method to a porcine data set in which stroke volume was measured with an ultrasonic flowmeter We obtain root-mean-square normalized errors of 11-13% across all pigs, lower than those obtained on the same data set using various other estimation methods. The CO estimates, and TPR estimates derived from them track intravenous drug infusions quite closely.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 50 条
  • [1] Model-Based Estimation of the Cardiac Output in Exercise Scenario
    Dan, Ana Maria
    2016 12TH IEEE INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND TELECOMMUNICATIONS (ISETC'16), 2016, : 285 - 288
  • [2] Resistance reconstructed: Estimation of total peripheral resistance from computationally-derived cardiac output
    Hill, LaBarron K.
    Sollers III, John J.
    Thayer, Julian F.
    Biomedical Sciences Instrumentation, 2013, 49 : 216 - 223
  • [3] Estimation of Cardiac Output and Total Peripheral Resistance in Preterm Infants by Arterial Waveform Analysis
    Zhang, Ying
    Chan, Gregory S. H.
    Tracy, Mark B.
    Hinder, Murray
    Redmond, Stephen J.
    Savkin, Andrey V.
    Lovell, Nigel H.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2308 - 2311
  • [4] CARDIAC OUTPUT AND TOTAL PERIPHERAL RESISTANCE IN ARTERIAL HYPEERTENSION
    GUEDON, J
    BUISSON, C
    LUCSKO, M
    COEUR ET MEDECINE INTERNE, 1971, 10 (03): : 413 - +
  • [5] Cardiac Output Versus Total Peripheral Resistance: A Wrinkle in Time
    Falkner, Bonita
    HYPERTENSION, 2018, 72 (05) : 1093 - 1094
  • [6] VENOUS RETURN AS AFFECTED BY CARDIAC OUTPUT AND TOTAL PERIPHERAL RESISTANCE
    RASHKIND, WJ
    LEWIS, DH
    HENDERSON, JB
    HEIMAN, DF
    DIETRICK, RB
    AMERICAN JOURNAL OF PHYSIOLOGY, 1953, 175 (03): : 415 - 423
  • [7] PLOTTING CARDIAC-OUTPUT VERSUS TOTAL PERIPHERAL RESISTANCE
    MROCHEN, H
    HIERONYMI, U
    KUCKELT, W
    CRITICAL CARE MEDICINE, 1981, 9 (02) : 129 - 131
  • [8] The effects of renin and angiotonin on cardiac output and total peripheral resistance
    Middleton, S
    Wiggers, CJ
    AMERICAN JOURNAL OF PHYSIOLOGY, 1944, 141 (01): : 0128 - 0131
  • [9] CARDIAC OUTPUT AND TOTAL PERIPHERAL RESISTANCE IN ANESTHESIOLOGY - CLINICAL APPLICATIONS
    GREENE, BA
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1958, 166 (09): : 1003 - 1010
  • [10] Cardiac output and total peripheral resistance measurements in experimental dogs
    Wiggers, HC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1944, 140 (04): : 0519 - 0534