Supported imidazolium ionic liquid phases: A new material for solid-phase extraction

被引:79
作者
Fontanals, Nuria [1 ]
Ronka, Sylwia [2 ]
Borrull, Francesc [1 ]
Trochimczuk, Andrzej W. [2 ]
Marce, Rosa M. [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43007, Spain
[2] Wroclaw Univ Technol, Fac Chem, Lab Polymer & Carbon Mat, PL-50370 Wroclaw, Poland
关键词
Supported ionic liquid phases; Solid-phase extraction; Anion exchange sorbent; Acidic compounds; Aqueous samples; WASTE-WATER; MASS-SPECTROMETRY; MICROEXTRACTION; CHROMATOGRAPHY; RESIDUES; SURFACE; PERFORMANCE; ENRICHMENT; SEPARATION; SOLVENTS;
D O I
10.1016/j.talanta.2009.06.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study reports a material that is based on the concept of ionic liquid analogue: a slightly crosslinked polymer-supported imidazolium trifluoroacetate salt (IL-CF3COO-) that favorably combines the properties of ionic liquids (ILs) and the advantages of a solid support. The ionic liquid-supported material was evaluated for the first time as a solid-phase extraction (SPE) sorbent for selectively and quantitatively extracting pharmaceuticals from aqueous samples. The novel IL-CF3COO- was evaluated under reversed-phase (RP), weak anion exchange (WAX), strong anion exchange (SAX) and strong cation exchange (SCX) SPE procedures, and we found that SAX conditions are the most suitable for investigating the behaviour of the IL-CF3CCO- material. Under SAX conditions. the IL-CF3COO- material was capable of selectively and quantitatively extracting a group of acidic compounds from aqueous samples, while washing basic analytes that were also present in the sample. The SPE method using IL-CF3COO- material was used to analyse 1000ml of different aqueous samples (ultrapure, tap and river) with complete recovery of the acidic compounds studied. Moreover, the method provided clean chromatogram and high recoveries when percolating complex real samples, such as 1000 ml of river water and 250 ml of effluent wastewater from a sewage treatment plant spiked at low levels with the analytes studied. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 256
页数:7
相关论文
共 34 条
[1]   Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters [J].
Aguilera-Herrador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) :106-111
[2]   Examination of ionic liquids and their interaction with molecules, when used as stationary phases in gas chromatography [J].
Armstrong, DW ;
He, LF ;
Liu, YS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3873-3876
[3]   Ionic liquids in separation techniques [J].
Berthod, A. ;
Ruiz-Angel, Mt ;
Carda-Broch, S. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :6-18
[4]   Ionic liquids as stationary phase solvents for methylated cyclodextrins in gas chromatography [J].
Berthod, A ;
He, L ;
Armstrong, DW .
CHROMATOGRAPHIA, 2001, 53 (1-2) :63-68
[5]   On-line preconcentration of pharmaceutical residues from large volume water samples using short reversed-phase monolithic cartridges coupled to LC-UV-ESI-MS [J].
Bones, Jonathan ;
Thomas, Kevin ;
Nesterenko, Pavel N. ;
Paull, Brett .
TALANTA, 2006, 70 (05) :1117-1128
[6]   Novel analytical procedures for screening of drug residues in water, waste water, sediment and sludge [J].
Buchberger, Wolfgang W. .
ANALYTICA CHIMICA ACTA, 2007, 593 (02) :129-139
[7]  
Carmichael AJ, 2000, J PHYS ORG CHEM, V13, P591, DOI 10.1002/1099-1395(200010)13:10<591::AID-POC305>3.0.CO
[8]  
2-2
[9]   Application of molecularly imprinted polymers to solid-phase extraction of compounds from environmental and biological samples [J].
Caro, E ;
Marcé, RM ;
Borrull, F ;
Cormack, PAG ;
Sherrington, DC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (02) :143-154
[10]   Determination of drugs in surface water and wastewater samples by liquid chromatography-mass spectrometry:: methods and preliminary results including toxicity studies with Vibrio fischeri [J].
Farré, ML ;
Ferrer, I ;
Ginebreda, A ;
Figueras, M ;
Olivella, L ;
Tirapu, L ;
Vilanova, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :187-197