Microembolic signal description: A reappraisal based on a customized digital postprocessing system

被引:9
作者
Mess, WH
Willigers, JM
Ledoux, LAF
Ackerstaff, RGA
Hoeks, APG
机构
[1] Maastricht Univ, Dept Clin Neurophysiol, Maastricht, Netherlands
[2] Maastricht Univ, Dept Biophys, Maastricht, Netherlands
[3] Cardiovasc Res Inst, Maastricht, Netherlands
[4] St Antonius Hosp, Dept Clin Neurophysiol, Nieuwegein, Netherlands
关键词
radiofrequency signal analysis; microembolic signals; transcranial Doppler sonography;
D O I
10.1016/S0301-5629(02)00618-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The high variability in presence and signature of microembolic signals (MES), detected with transcranial Doppler sonography (TCD) in the middle cerebral artery (MCA), cannot be explained with the currently available published data. We applied customized postprocessing on the radiofrequency (RF) signal of a standard TCD system. The spatial resolution was on the order of 2 mm, depending only on the length of the ultrasound (US) burst emitted. The amplitude of clutter-filtered RF signals was color-coded and plotted as a function of time and depth (range 30 mm). Additionally, 128 point fast Fourier transforms (FFTs) (50% temporal overlap) were calculated, visualizing both the background Doppler spectrum and the MES. We evaluated 122 gaseous MES from two patients during cardiac surgery and 52 particulate MES from four patients after carotid endarterectomy. Both MES categories showed comparable properties: they appeared in the RF amplitude plot as rather straight lines of increased intensity, indicating that the velocity remained approximately the same while they passed the US beam. The velocity calculated from the amplitude plot never exceeded that of the background Doppler spectrum. Various "MES patterns" could be identified with respect to the depth range at which the MES were visible. A quarter of the gaseous MES changed their direction at a specific depth, suggesting that the MES entered a branch (e.g., an M2 artery or the anterior cerebral artery). In the FFT analysis, these MES contained both positive and negative frequencies. It is concluded that MES show consistent signature patterns in the amplitude-time plots and that the previously reported variability of MES appearance in conventional Doppler systems is an artefact caused by relatively large signal amplitudes and sample volumes. (E-mail: Max@fknf.azm.nl) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1447 / 1455
页数:9
相关论文
共 15 条
[1]   The use of the wavelet transform to describe embolic signals [J].
Aydin, N ;
Padayachee, S ;
Markus, HS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06) :953-958
[2]  
Brands P J, 1999, Eur J Ultrasound, V9, P257, DOI 10.1016/S0929-8266(99)00033-6
[3]   Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves [J].
Droste, DW ;
Hagedorn, G ;
Notzold, A ;
Siemens, HJ ;
Sievers, HH ;
Kaps, M .
STROKE, 1997, 28 (03) :588-592
[4]   A REAL-TIME AND FINE RESOLUTION ANALYZER USED TO ESTIMATE THE INSTANTANEOUS ENERGY-DISTRIBUTION OF DOPPLER SIGNALS [J].
FAN, LK ;
EVANS, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (05) :445-454
[5]   Tail sign associated with microembolic signals [J].
Furui, E ;
Hanzawa, K ;
Ohzeki, H ;
Nakajima, T ;
Fukuhara, N ;
Takamori, M .
STROKE, 1999, 30 (04) :863-866
[6]   Automated intraoperative detection of Doppler microembolic signals using the Bigate approach [J].
Georgiadis, D ;
Wenzel, A ;
Zerkowski, HR ;
Zierz, S ;
Lindner, A .
STROKE, 1998, 29 (01) :137-139
[7]   A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation [J].
Georgiadis, D ;
Goeke, J ;
Hill, M ;
Konig, M ;
Nabavi, DG ;
Stogbauer, F ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (04) :683-686
[8]   Frequency filtering improves ultrasonic embolic signal detection [J].
Markus, HS ;
Reid, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (05) :857-860
[9]   Middle cerebral artery anatomy and characteristics of embolic signals: A dual gate computer simulation study [J].
Mess, WH ;
Titulaer, BM ;
Ackerstaff, RGA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (04) :531-539
[10]   A new algorithm for off-line automated emboli detection based on the pseudo-Wigner power distribution and the dual gate TCD technique [J].
Mess, WH ;
Titulaer, BM ;
Ackerstaff, RGA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :413-418