Transient Responses of the Doubly-Fed Induction Generator Wind Turbine under Grid Fault Conditions

被引:0
作者
Phan, T. T. [1 ]
Nguyen, V. L. [2 ]
Hossain, M. J. [1 ]
To, A. N. [3 ]
Tran, H. T. [3 ]
Phan, T. N. [4 ]
机构
[1] Griffith Univ, Griffith Sch Engn, Gold Coast, Australia
[2] Ho Chi Minh Univ Technol, Fac Elect Elect Engn, Ho Chi Minh City, Vietnam
[3] Can Tho Univ Technol, Fac Elect Elect & Telecommun Engn, Can Tho, Vietnam
[4] Can Tho Univ, Coll Engn Technol, Can Tho, Vietnam
来源
2016 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP) | 2016年
关键词
Doubly-fed induction generator; active and reactive power control; distribution static compensator; grid fault ride-through capability; VOLTAGE; DFIG;
D O I
10.1109/ACOMP.2016.13
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Doubly-fed induction generator (DFIG) wind turbine (WT) is an integrated part of distributed generation system. The use of DFIG in wind farms is growing rapidly because of its advantages in decoupled active and reactive power control. However, one of the main disadvantages of DFIG is that it is very sensitive to grid faults. To analysis dynamic behaviors of DFIG during grid faults, a model including wind wheel, wind speed, drive train, generator, and converters has been proposed. This paper examines the use of distribution static compensator (D-STATCOM) as a dynamic voltage restorer at the point of common coupling (PCC) to improve the grid fault ride-through (FRT) capability and thereby protecting system stability during disturbances. The simulation results illustrate the transient responses of DFIG when a sudden short circuit at PCC is introduced. Besides, the paper also shows detailed comparisons of the transient behaviors between DFIG and conventional induction generator wind turbine under grid fault conditions.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 15 条
[1]  
Chowdhury M., 2015, INT J SUSTAINABLE EN, P1
[2]   Dynamic modeling of doubly fed induction generator wind turbines [J].
Ekanayake, JB ;
Holdsworth, L ;
Wu, XG ;
Jenkins, N .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) :803-809
[3]   Simultaneous STATCOM and Pitch Angle Control for Improved LVRT Capability of Fixed-Speed Wind Turbines [J].
Hossain, M. Jahangir ;
Pota, Hemanshu R. ;
Ugrinovskii, Valeri A. ;
Ramos, Rodrigo A. .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2010, 1 (03) :142-151
[4]   Improved Control of DFIG Systems During Network Unbalance Using PI-R Current Regulators [J].
Hu, Jiabing ;
He, Yikang ;
Xu, Lie ;
Williams, Barry W. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) :439-451
[5]   International comparison of requirements for connection of wind turbines to power systems [J].
Jauch, C ;
Matevosyan, J ;
Ackermann, T ;
Bolik, S .
WIND ENERGY, 2005, 8 (03) :295-306
[6]  
Koessler R., 2015, P IEEE PES GEN M, V3, P1511
[7]   Study of Fault Current Characteristics of the DFIG Considering Dynamic Response of the RSC [J].
Kong, Xiangping ;
Zhang, Zhe ;
Yin, Xianggen ;
Wen, Minghao .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) :278-287
[8]   Low and high voltage ride-through of DFIG wind turbines using hybrid current controlled converters [J].
Mohseni, Mansour ;
Masoum, Mohammad A. S. ;
Islam, Syed M. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) :1456-1465
[9]  
Nguyen TT, 2005, IEEE POWER ENG SOC, P2927
[10]  
Ouyang J., 2009, RENEW ENERG, V71, P629