Ytterbium(III)-selective membrane electrode based on cefixime

被引:96
作者
Ganjali, MR [1 ]
Naji, L
Poursaberi, T
Shamsipur, M
Haghgoo, S
机构
[1] Univ Tehran, Dept Chem, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[3] Razi Univ, Dept Chem, Khorramshahr, Iran
[4] Ctr Qual Control Drugs, Tehran, Iran
关键词
Ytterbium ion-selective electrode; PVC membrane; cefixime; potentiometry;
D O I
10.1016/S0003-2670(02)01226-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have discovered that the antibiotic cefixime (CFI) can be used as a suitable ionophore in PVC membranes having interesting response characteristics for Yb3+ ions. The selective complexation behavior of cefixime with Yb3+ over different metal ions was studied in DMSO solution. The negligible water solubility of cefixime and the increased stability and selectivity of its Yb3+ complex make the antibiotic an attractive ionophore for use in potentiometric poly (vinyl chloride) membrane electrodes for Yb3+. The results revealed a Nemstian response to Yb3+ over concentration range 1.0 x 10(-2)-1.0 x 10(-6) M as well as improved selectivity against a wide range of common interferences. The sensor possesses a detection limit of 7.0 x 10(-7) M and can be used in a pH range 3.0-8.0 for at least 8 weeks. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 36 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]   Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato)alkanes [J].
Chowdhury, DA ;
Ogata, T ;
Kamata, S ;
Ohashi, K .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :366-370
[3]   Silver(I)-selective membrane electrodes based on sulfur-containing podands [J].
Chung, S ;
Kim, W ;
Park, SB ;
Kim, DY ;
Lee, SS .
TALANTA, 1997, 44 (07) :1291-1298
[4]   RARE-EARTHS FROM SUPERNOVA TO SUPERCONDUCTOR [J].
CORNELL, DH .
PURE AND APPLIED CHEMISTRY, 1993, 65 (12) :2453-2464
[5]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[6]   Lead-selective membrane potentiometric sensor based on a recently synthesized dimethyl benzo tetrathia fulvalene [J].
Fathi, MR ;
Darviche, F ;
Ganjali, MR .
ANALYTICAL LETTERS, 2000, 33 (06) :1025-1035
[7]   Nickel(II) ion-selective electrode based on 2,5-thiophenyl bis(5-tert-butyl-1,3-benzoxazole) [J].
Ganjali, MR ;
Hosseini, SM ;
Javanbakht, M ;
Hashemi, OR .
ANALYTICAL LETTERS, 2000, 33 (15) :3139-3152
[8]  
Ganjali MR, 2000, ELECTROANAL, V12, P1138
[9]  
GANJALI MR, 2001, ANAL CHIM ACTA, V81, P401
[10]  
GANJALI MR, 1993, ANAL CHEM, V65, P2453