A compact high resolution electrospray ionization ion mobility spectrometer

被引:31
|
作者
Reinecke, T. [1 ]
Kirk, A. T. [1 ]
Ahrens, A. [1 ]
Raddatz, C. -R. [1 ]
Thoben, C. [1 ]
Zimmermann, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Elect Engn & Measurement Technol, Appelstr 9A, D-30167 Hannover, Germany
关键词
Ion mobility spectrometry; Electrospray; Water analysis; Three grid ion shutter; GAS;
D O I
10.1016/j.talanta.2015.12.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray is a commonly used ionization method for the analysis of liquids. An electrospray is a dispersed nebular of charged droplets produced under the influence of a strong electrical field. Subsequently, ions are produced in a complex process initiated by evaporation of neutral solvent molecules from these droplets. We coupled an electrospray ionization source to our previously described high resolution ion mobility spectrometer with 75 mm drift tube length and a drift voltage of 5 kV. When using a tritium source for chemical gas phase ionization, a resolving power of R=100 was reported for this setup. We replaced the tritium source and the field switching shutter by an electrospray needle, a desolvation region with variable length and a three-grid shutter for injecting ions into the drift region. Preliminary measurements with tetraalkylammonium halides show that the current configuration with the electrospray ionization source maintains the resolving power of R=100. In this work, we present the characterization of our setup. One major advantage of our setup is that the desolvation region can be heated separately from the drift region so that the temperature in the drift region stays at room temperature even up to desolvation region temperatures of 100 degrees C. We perform parametric studies for the investigation of the influence of temperature on solvent evaporation with different ratios of water and methanol in the solvent for different analyte substances. Furthermore, the setup is operated in negative mode and spectra of bentazon with different solvents are presented. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Li Zhou
    David C. Collins
    Edgar D. Lee
    Milton L. Lee
    Analytical and Bioanalytical Chemistry, 2007, 388 : 189 - 194
  • [42] Mechanical ion gate for electrospray-ionization ion-mobility spectrometry
    Zhou, Li
    Collins, David C.
    Lee, Edgar D.
    Lee, Milton L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (01) : 189 - 194
  • [43] Two-dimensional separations with electrospray ionization ambient pressure high-resolution ion mobility spectrometry/quadrupole mass spectrometry
    Matz, LM
    Asbury, GR
    Hill, HH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (07) : 670 - 675
  • [44] Determination of Artificial Sweeteners by High-Performance Ion-Mobility Spectrometry with Electrospray Ionization
    Sha, Min
    Zhang, Zhengyong
    Liu, Jun
    Wang, Haiyan
    ANALYTICAL LETTERS, 2017, 50 (06) : 936 - 944
  • [45] A new, higher resolution, ion mobility mass spectrometer
    Kemper, Paul R.
    Dupuis, Nicholas F.
    Bowers, Michael T.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 287 (1-3) : 46 - 57
  • [46] Increasing specificity in a low resolution ion mobility spectrometer
    Fulton, J
    Griffin, MT
    Gao, R
    Tsoukalas, L
    CHEMICAL AND BIOLOGICAL SENSING III, 2002, 4722 : 78 - 85
  • [47] Novel Ultra Compact and High Resolution Spectrometer
    Yang, T.
    Li, C. C.
    Ho, H. P.
    2009 14TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC 2009), 2009, : 312 - 313
  • [48] Development of an ion mobility spectrometer with a paper spray ionization source
    Zhang Jingjing
    Jiang Jie
    Qiao Xiaolin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):
  • [49] Design and experiment of a laser ionization source for ion mobility spectrometer
    JI Ren-dong*
    OptoelectronicsLetters, 2006, (05) : 399 - 402
  • [50] Design and experiment of a laser ionization source for ion mobility spectrometer
    Ren-dong Ji
    Xiang-he Kong
    Xian-yun Liu
    Shu-dong Zhang
    Optoelectronics Letters, 2006, 2 (5) : 399 - 402