Pinhole SPECT with different data acquisition geometries: Usefulness of unified projection operators in homogeneous coordinates

被引:45
作者
Wang, Yuchuan [1 ]
Tsui, Benjamin M. W. [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Radiol, Div Med Imaging Phys, Baltimore, MD 21287 USA
关键词
calibration; emission computed tomography; geometry; image reconstruction; single photon;
D O I
10.1109/TMI.2006.887372
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To further improve pinhole single photon emission computed tomography (SPECT) imaging, there have been increasing interests in the use of nonstandard collimator designs and/or acquisition geometries. Homogeneous coordinates provide a compact and convenient framework to unify the geometric descriptions of the projection operators for these different imaging geometries, which may facilitate the implementation of iterative reconstruction algorithms and the investigation of crucial geometric calibration problems in pinhole SPECT. In this work, these advantages were demonstrated through three examples, namely, multipinhole SPECT, pinhole SPECT with a helical scanning orbit, and pinhole SPECT with dual detectors. Specifically, we showed adaptable implementations of iterative image reconstruction algorithms and translatable strategies for efficient geometric calibrations through unifying projection operators of the aforementioned imaging geometries. Notably, the unified geometric descriptions of multipinhole and single pinhole projection operators allowed us to derive that one can effectively calibrate a multipinhole geometry using only two point sources without measuring their distance. Experimental studies were performed to demonstrate the validity of our approaches, which may be extended to other pinhole SPECT and cone-beam X-ray computed tomography imaging geometries.
引用
收藏
页码:298 / 308
页数:11
相关论文
共 28 条
  • [1] Occupancy of dopamine D2 receptors in the mouse brain measured using ultra-high-resolution single-photon emission tomography and [123I]IBF
    Acton, PD
    Hou, C
    Kung, MP
    Plössl, K
    Keeney, CL
    Kung, HF
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (11) : 1507 - 1515
  • [2] Beekman FJ, 2005, J NUCL MED, V46, P1194
  • [3] Optimization of geometrical calibration in pinhole SPECT
    Bequé, D
    Nuyts, J
    Suetens, P
    Bormans, G
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) : 180 - 190
  • [4] Characterization of pinhole SPECT acquisition geometry
    Bequé, D
    Nuyts, J
    Bormans, G
    Suetens, P
    Dupont, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) : 599 - 612
  • [5] HOMOGENEOUS COORDINATES FOR COMPUTER-GRAPHICS
    BEZ, HE
    [J]. COMPUTER-AIDED DESIGN, 1983, 15 (06) : 361 - 365
  • [6] HOMOGENEOUS COORDINATES
    BLOOMENTHAL, J
    ROKNE, J
    [J]. VISUAL COMPUTER, 1994, 11 (01) : 15 - 26
  • [7] Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements
    Bronnikov, AV
    [J]. OPTICAL ENGINEERING, 1999, 38 (02) : 381 - 386
  • [8] FastSPECT II: A second-generation high-resolution dynamic SPECT imager
    Furenlid, LR
    Wilson, DW
    Chen, YC
    Kim, H
    Pietraski, PJ
    Crawford, MJ
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 631 - 635
  • [9] Cone-beam reprojection using projection-matrices
    Galigekere, RR
    Wiesent, K
    Holdsworth, DW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (10) : 1202 - 1214
  • [10] ESTIMATION OF GEOMETRICAL PARAMETERS AND COLLIMATOR EVALUATION FOR CONE BEAM TOMOGRAPHY
    GULLBERG, GT
    TSUI, BMW
    CRAWFORD, CR
    BALLARD, JG
    HAGIUS, JT
    [J]. MEDICAL PHYSICS, 1990, 17 (02) : 264 - 272