Multimodal x-ray scatter imaging

被引:136
|
作者
Bunk, O. [1 ]
Bech, M. [2 ]
Jensen, T. H. [3 ]
Feidenhans'l, R. [3 ]
Binderup, T. [4 ,5 ]
Menzel, A. [1 ]
Pfeiffer, F. [2 ,6 ,7 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Tech Univ Munich, Dept Phys E17, D-85748 Garching, Germany
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[4] Rigshosp, DK-2100 Copenhagen, Denmark
[5] Univ Copenhagen, Fac Hlth Sci, DK-2100 Copenhagen, Denmark
[6] Paul Scherrer Inst, CH-1015 Lausanne, Switzerland
[7] Ecole Polytech Fed Lausanne, CH-1015 Lausanne, Switzerland
来源
NEW JOURNAL OF PHYSICS | 2009年 / 11卷
关键词
BREAST-TISSUE; DETECTOR; PILATUS; DIFFRACTION; ORIENTATION; SAXS; TOOL;
D O I
10.1088/1367-2630/11/12/123016
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We describe a small-angle x-ray scattering-based imaging technique that reveals the distribution and orientation of nano-scale structures over extended areas. By combining two measurement and analysis schemes, complementary structural information is available which renders the technique suitable for a broad range of applications, e. g. in materials science and bio-imaging. Through a combination of current techniques and on-line analysis schemes, measurements with a so far unprecedented combination of speed, dynamic range and point density became feasible. This is illustrated by data recorded for a section of a mouse soleus muscle visualizing fine muscle and Achilles tendon structures down to the 10 nm range over a 10 mm(2) sample area.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Coded apertures for x-ray scatter imaging
    Brady, David J.
    Marks, Daniel L.
    MacCabe, Kenneth P.
    O'Sullivan, Joseph A.
    APPLIED OPTICS, 2013, 52 (32) : 7745 - 7754
  • [2] Nanomaterials for X-ray Imaging: Gold Nanoparticle Enhancement of X-ray Scatter Imaging of Hepatocellular Carcinoma
    Rand, Danielle
    Ortiz, Vivian
    Liu, Yanan
    Derdak, Zoltan
    Wands, Jack R.
    Taticek, Milan
    Rose-Petruck, Christoph
    NANO LETTERS, 2011, 11 (07) : 2678 - 2683
  • [3] Compton Scatter in X-Ray Fluorescence CT Imaging
    Bazalova, M.
    Kuang, Y.
    Pratx, G.
    Xing, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3986 - 3986
  • [4] X-Ray Scatter Reduction in Tomosynthesis Imaging of the Breast
    Sechopoulos, I.
    Feng, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [5] On scatter in megavoltage x-ray transmission imaging (in English)
    Spies, L
    MEDICAL PHYSICS, 2000, 27 (03) : 624 - 624
  • [6] Radiochromic film dosimetry for x-ray scatter imaging
    Dydula, Christopher
    Beaton-Green, Lindsay A.
    Johns, Paul C.
    Wardlaw, Graeme
    MEDICAL PHYSICS, 2021, 48 (08) : 4695 - 4695
  • [7] Benchtop Coherent X-Ray Scatter Projection Imaging: From Synchrotrons to X-Ray Tubes
    Dydula, C.
    Johns, P. C.
    MEDICAL PHYSICS, 2020, 47 (06) : E383 - E383
  • [8] Analysis of spectral blur effects in x-ray scatter imaging
    Leclair, RJ
    Johns, PC
    MEDICAL PHYSICS, 1999, 26 (09) : 1811 - 1816
  • [9] Coherent scatter x-ray imaging of plastic/water phantoms
    Nisar, M
    Johns, PC
    PHOTONICS NORTH: APPLICATIONS OF PHOTONIC TECHNOLOGY 7B, PTS 1 AND 2: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION - PHOTONIC APPLICATIONS IN ASTRONOMY, BIOMEDICINE, IMAGING, MATERIALS PROCESSING, AND EDUCATION, 2004, 5578 : 445 - 453
  • [10] Pencil beam coded aperture x-ray scatter imaging
    MacCabe, Kenneth
    Krishnamurthy, Kalyani
    Chawla, Amarpreet
    Marks, Daniel
    Samei, Ehsan
    Brady, David
    OPTICS EXPRESS, 2012, 20 (15): : 16310 - 16320