Effect of strength and fiber reinforcement on fire resistance of high-strength concrete columns

被引:182
|
作者
Kodur, VKR [1 ]
Cheng, FP
Wang, TC
Sultan, MA
机构
[1] Natl Res Council Canada, Inst Res Construct, Ottawa, ON K1A 0R6, Canada
[2] Natl Chiao Tung Univ, Dept Civil Engn, Hsinchu, Taiwan
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2003年 / 129卷 / 02期
关键词
fire resistance; high-strength concrete; concrete columns; temperature; fiber-reinforced materials;
D O I
10.1061/(ASCE)0733-9445(2003)129:2(253)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, results from fire resistance experiments on five types of reinforced concrete columns are presented. The variables considered in the study include concrete strength [normal-strength concrete (NSC) and high-strength concrete (HSC)], aggregate type (siliceous and carbonate aggregate), and fiber reinforcement (steel and polypropylene fibers). Data from the study is used to determine the structural behavior of HSC columns at elevated temperatures. A comparison is made of the fire resistance performance of HSC columns with that of NSC and fiber-reinforced HSC columns. The factors that influence the thermal and structural behavior of HSC concrete columns under fire conditions are discussed. The results show that the fire resistance of a NSC column is higher than that of a HSC column. Also, the addition of polypropylene fibers and the use of carbonate aggregate improve fire resistance.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 50 条
  • [21] Seismic Performance and Confinement Reinforcement Design of High-Strength Concrete Columns Confined with High-Strength Stirrups
    Yang, Kun
    Shi, Qing-xuan
    Lin, Qi
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (10) : 2061 - 2075
  • [22] Experimental investigation on fire resistance of high-strength concrete encased steel composite columns
    Li, Shan
    Liew, J. Y. Richard
    Xiong, Ming-Xiang
    Lai, Bing-Lin
    FIRE SAFETY JOURNAL, 2021, 121
  • [23] Bond strength of reinforcement in high-strength concrete
    Mendis, P.
    French, C.
    Advances in Structural Engineering, 2000, 3 (03) : 245 - 253
  • [24] Axial Load Response of Ultra-High-Strength Concrete Columns and High-Strength Reinforcement
    Shin, Hyun-Oh
    Yoon, Young-Soo
    Cook, William D.
    Mitchell, Denis
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 325 - 336
  • [25] Fire resistance of corroded high-strength structural concrete
    Sobhan, Khaled
    Reddy, Dronnadula V.
    Martinez, Fernando
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2021, 12 (01) : 17 - 34
  • [26] Spun concrete piece of high-strength and ultra high-strength concrete reinforcement
    Mueller, Corinna
    Empelmann, Martin
    Hude, Florian
    Adam, Thomas
    BETON- UND STAHLBETONBAU, 2012, 107 (10) : 690 - 699
  • [27] Strength and ductility simulation of high-strength concrete columns
    Diniz, SMC
    Frangopol, DM
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (10): : 1365 - 1374
  • [28] Design of high-strength concrete columns for strength and ductility
    Saatcioglu, M
    ART AND SCIENCE OF STRUCTURAL CONCRETE DESIGN: A SYMPOSIUM HONORING RICHARD W. FURLONG, 2003, 213 : 83 - 101
  • [29] STRENGTH AND DEFORMABILITY OF CONFINED HIGH-STRENGTH CONCRETE COLUMNS
    RAZVI, SR
    SAATCIOGLU, M
    ACI STRUCTURAL JOURNAL, 1994, 91 (06) : 678 - 687
  • [30] Seismic performance of semi-precast high-strength recycled aggregate concrete columns with high-strength reinforcement
    Zhang, Jianwei
    Tao, Xinyi
    Liu, Juan
    Dong, Hongying
    Cao, Wanlin
    JOURNAL OF BUILDING ENGINEERING, 2022, 45