State of the art: implantable ventricular assist devices

被引:40
作者
Lahpor, J. R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Div Heart & Lung, Dept Heart & Lung, NL-3584 CX Utrecht, Netherlands
关键词
bridge to transplantation; chronic heart failure; HeartMate; 2; mechanical circulatory support; HEART-FAILURE; PULMONARY-HYPERTENSION; DESTINATION THERAPY; CONTINUOUS-FLOW; BRIDGE; SUPPORT; TRANSPLANT; SYSTEM; EXPERIENCE; OUTCOMES;
D O I
10.1097/MOT.0b013e3283303750
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Purpose of review The first generation of implantable pulsatile ventricular assist devices (VADs) has proven to be successful as bridge to transplantation. Adverse events such as mechanical failure and infections, however, limit their use for long-term support (>1 year) or as alternative for heart transplantation. Newer second generation of nonpulsatile VADs shows less of such limitations. Recent findings As bridge to transplantation, we have seen a switch from pulsatile volume-displacement devices, like the HeartMate XVE LVAS and Novacor left ventricular assist device (LVAD), (first generation) to continuous flow devices like the HeartMate 2 and Berlin Heart Incor (second generation). These devices are smaller, quiet and mechanically more durable. Better long-term survival, lower infection rates, excellent mechanical durability and acceptable quality of life together with shortage of donor organs led also to an increasing usage of these devices as alternative to transplantation. Recent studies show in this respect encouraging results, with actuarial survival rates at 1 and 2 years of 70% or higher. Another result of long-term cardiac support is a bridge to recovery. Initial results of even smaller implantable centrifugal pumps like the HeartWare VAD are promising. Summary An overview of recent developments in mechanical circulatory support is presented.
引用
收藏
页码:554 / 559
页数:6
相关论文
共 35 条
[1]   Success rates of long-term circulatory assist devices used currently for bridge to heart transplantation [J].
Arabia, FA ;
Smith, RG ;
Rose, DS ;
Arzouman, DA ;
Sethi, GK ;
Copeland, JG .
ASAIO JOURNAL, 1996, 42 (05) :M542-M546
[2]   Left ventricular assist device and drug therapy for the reversal of heart failure [J].
Birks, Emma J. ;
Tansley, Patrick D. ;
Hardy, James ;
George, Robert S. ;
Bowles, Christopher T. ;
Burke, Margaret ;
Banner, Nicholas R. ;
Khaghani, Asghar ;
Yacoub, Magdi H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (18) :1873-1884
[3]   Past, Present, and Future of Long-Term Mechanical Cardiac Support in Adults [J].
Christiansen, Stefan ;
Klocke, Anna ;
Autschbach, Ruediger .
JOURNAL OF CARDIAC SURGERY, 2008, 23 (06) :664-676
[4]   Outcomes and long-term quality-of-life of patients supported by extyacorpoyeal membrane oxygenation for refractory caydiogenic shock [J].
Combes, Alain ;
Leprince, Pascal ;
Luyt, Charles-Edouard ;
Bonnet, Nicolas ;
Trouillet, Jean-Louis ;
Leger, Philippe ;
Pavie, Alain ;
Chastre, Jean .
CRITICAL CARE MEDICINE, 2008, 36 (05) :1404-1411
[5]  
Deng MC., 2007, Mechanical Circulatory Support Therapy in Advanced Heart Failure
[6]   Initial experience with the AbioCor Implantable Replacement Heart System [J].
Dowling, RD ;
Gray, LA ;
Etoch, SW ;
Laks, H ;
Marelli, D ;
Samuels, L ;
Entwistle, J ;
Couper, G ;
Vlahakes, GJ ;
Frazier, OH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (01) :131-141
[7]   CardioWest total artificial heart: Bad oeynhausen experience [J].
El-Banayosy, A ;
Arusoglu, L ;
Morshuis, M ;
Kizner, L ;
Tenderich, G ;
Sarnowski, P ;
Milting, H ;
Koerfer, R .
ANNALS OF THORACIC SURGERY, 2005, 80 (02) :548-552
[8]   Novacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients:: A prospective study [J].
El-Banayosy, A ;
Arusoglu, L ;
Kizner, L ;
Tenderich, G ;
Minami, K ;
Inoue, K ;
Körfer, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (03) :581-587
[9]   A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: Safety and efficacy [J].
Esmore, Donald ;
Kaye, David ;
Spratt, Phillip ;
Larbalestier, Robert ;
Ruygrok, Peter ;
Tsui, Steven ;
Meyers, Deborah ;
Fiane, Arnt E. ;
Woodard, John .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (06) :579-588
[10]   Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation [J].
Frazier, OH ;
Rose, EA ;
Oz, MC ;
Dembitsky, W ;
McCarthy, P ;
Radovancevic, B ;
Poirier, VL ;
Dasse, KA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (06) :1186-1195