Methylene blue as an indicator for sensitive electrochemical detection of adenosine based on aptamer switch

被引:69
作者
Wang, Jianlong
Wang, Fuan
Dong, Shaojun [1 ]
机构
[1] Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
关键词
Electrochemistry; Aptamer; Methylene blue; Displacement; Biosensor; LABEL-FREE; DNA; MOLECULES; GUANINE; ARRAYS; SENSOR; SERUM;
D O I
10.1016/j.jelechem.2008.08.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a simple, label-free and regenerative method was proposed to study the interaction between aptamer and small molecule by using methylene blue (MB+) as an electrochemical indicator. A thiolated capture probe containing twelve bases was firstly self-assembled on gold electrode by gold-sulfur affinity. Aptamer probe containing thirty two bases, which was designed to hybridize with capture DNA sequence and specifically recognize adenosine, was then immobilized on the electrode surface by hybridization reaction. MB+ was abundantly adsorbed on the aptamer probe by the specific interaction between MB+ and guanine base in aptamer probe. MB+-anchored aptamer probe can be forced to dissociate from the sensing interface after adenosine triggered structure switching of the aptamer. The peak current of MB+ linearly decreased with the concentration of adenosine over a range of 2 x 10 (8)- x 10 (6) M with a detection limit of 1 x 10 (8) M. In addition, we examined the selectivity of this electrochemical biosensor for cytidine, uridine and guanosine that belonged to the nucleosides family and possessed 1 similar structure with adenosine. The peak Current of MB+ slightly decreased even then 1 mM cytidine, uridine or guanosine was added to reaction cell for 2 h, which confirmed this biosensor had a good selectivity for adenosine. After each of detection, the electrode was immersed into aptamer solution for regeneration. The recovery of the electrochemical signal of MB+ indicated the sensor surface of electrode was successfully regenerated. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 31 条
[1]  
Baker BR, 2006, J AM CHEM SOC, V128, P3138, DOI 10.1021/ja056957p
[2]   A novel electrochemical detection method for aptamer biosensors [J].
Bang, GS ;
Cho, S ;
Kim, BG .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :863-870
[3]   Label-free protein recognition using an aptamer-based impedance measurement assay [J].
Cai, H ;
Lee, TMH ;
Hsing, IM .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :433-437
[4]   DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF ADENINE, CYTOSINE, AND THEIR NUCLEOSIDES [J].
CUMMINGS, TE ;
FRASER, JR ;
ELVING, PJ .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :558-561
[5]   ELECTROCHEMICAL OXIDATION OF GUANINE AT PYROLYTIC GRAPHITE ELECTRODE [J].
DRYHURST, G ;
PACE, GF .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1970, 117 (10) :1259-&
[6]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[7]   Label-free electrochemical detection of nanomolar adenosine based on target-induced aptamer displacement [J].
Feng, Kejun ;
Sun, Chenhu ;
Kang, Yan ;
Chen, Jiwei ;
Jiang, Jian-Hui ;
Shen, Guo-Li ;
Yu, Ru-Qin .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (04) :531-535
[8]   The electrochemical behavior of methylene blue at a microcylinder carbon fiber electrode [J].
Ju, HX ;
Zhou, J ;
Cai, CX ;
Chen, HY .
ELECTROANALYSIS, 1995, 7 (12) :1165-1170
[9]   Voltammetric determination of DNA hybridization using methylene blue and self-assembled alkanethiol monolayer on gold electrodes [J].
Kerman, K ;
Ozkan, D ;
Kara, P ;
Meric, B ;
Gooding, JJ ;
Ozsoz, M .
ANALYTICA CHIMICA ACTA, 2002, 462 (01) :39-47
[10]   Purine sensing by riboswitches [J].
Kim, Jane N. ;
Breaker, Ronald R. .
BIOLOGY OF THE CELL, 2008, 100 (01) :1-11