Reproducibility of Intra- and Interscanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla

被引:20
作者
Wu, Bing [1 ]
Han, Wei [1 ]
Li, Zhenhong [2 ]
Zhao, Yonghua [2 ]
Ge, Mingmei [1 ]
Guo, Xueqing [3 ]
Wu, Xinhuai [1 ]
机构
[1] Beijing Mil Gen Hosp, Dept Radiol, Beijing, Peoples R China
[2] PLA 263 Hosp, Dept Radiol, Beijing, Peoples R China
[3] PLA 263 Hosp, Dept Clin Lab, Beijing, Peoples R China
关键词
FLIP-ANGLE; WATER; QUANTIFICATION; SEPARATION; ACCURATE; FRACTION; IDEAL; T-1;
D O I
10.1038/srep19339
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study was to prospectively evaluate the reproducibility of the proton density fatfraction (PDFF) of the liver using the IDEAL algorithm, a quantitative confounder-corrected chemicalshift-encoded MRI method. Data were obtained from 15 volunteers on four different days. The first and the third examinations were conducted on scanner one with one-week intervals, while the second and the fourth tests were performed on scanner two with same time interval. For each test, two MR scans were performed, one before and one after a meal. Regions-of-interest measurements were manually calculated to estimate the PDFF in the right and left lobes on the PDFF images. Reproducibility was measured using the intra-class correlation coefficient (ICC). The ICCs of the PDFF in the right and left lobes were 0.935 and 0.878, respectively. The intra-scanner ICCs of the right lobe before and after a meal or at a one-week interval were 0.924 and 0.953, respectively. The inter-scanner ICCs of PDFF the next day and at a one-week interval were 0.920 and 0.864, respectively. The PDFF of liver derived from IDEAL demonstrated high intra-and inter-scanner measurement reproducibility. The PDFF of the right lobe before a meal was more reproducible than after-meal measurements.
引用
收藏
页数:6
相关论文
共 13 条
[1]   T1 Independent, T2* Corrected Chemical Shift Based Fat-Water Separation With Multi-peak Fat Spectral Modeling Is an Accurate and Precise Measure of Hepatic Steatosis [J].
Hines, Catherine D. G. ;
Frydrychowicz, Alex ;
Hamilton, Gavin ;
Tudorascu, Dana L. ;
Vigen, Karl K. ;
Yu, Huanzhou ;
McKenzie, Charles A. ;
Sirlin, Claude B. ;
Brittain, Jean H. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :873-881
[2]   Effect of Flip Angle on the Accuracy and Repeatability of Hepatic Proton Density Fat Fraction Estimation by Complex Data-Based, T1-Independent, T2*-Corrected, Spectrum-Modeled MRI [J].
Johnson, Benjamin L. ;
Schroeder, Michael E. ;
Wolfson, Tanya ;
Gamst, Anthony C. ;
Hamilton, Gavin ;
Shiehmorteza, Masoud ;
Loomba, Rohit ;
Schwimmer, Jeffrey B. ;
Reeder, Scott ;
Middleton, Michael S. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) :440-447
[3]   Reproducibility of MRI-Determined Proton Density Fat Fraction Across Two Different MR Scanner Platforms [J].
Kang, Geraldine H. ;
Cruite, Irene ;
Shiehmorteza, Masoud ;
Wolfson, Tanya ;
Gamst, Anthony C. ;
Hamilton, Gavin ;
Bydder, Mark ;
Middleton, Michael S. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) :928-934
[4]   Fat quantification with IDEAL gradient echo imaging:: Correction of bias from T1 and noise [J].
Liu, Chia-Ying ;
McKenzie, Charles A. ;
Yu, Huanzhou ;
Brittain, Jean H. ;
Reeder, Scott B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) :354-364
[5]   Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy [J].
Meisamy, Sina ;
Hines, Catherine D. G. ;
Hamilton, Gavin ;
Sirlin, Claude B. ;
McKenzie, Charles A. ;
Yu, Huanzhou ;
Brittain, Jean H. ;
Reeder, Scott B. .
RADIOLOGY, 2011, 258 (03) :767-775
[6]   Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging [J].
Reeder, SB ;
Pineda, AR ;
Wen, ZF ;
Shimakawa, A ;
Yu, HZ ;
Brittain, JH ;
Gold, GE ;
Beaulieu, CH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) :636-644
[7]   Quantification of Hepatic Steatosis With MRI: The Effects of Accurate Fat Spectral Modeling [J].
Reeder, Scott B. ;
Robson, Philip M. ;
Yu, Huanzhou ;
Shimakawa, Ann ;
Hines, Catherine D. G. ;
McKenzie, Charles A. ;
Brittain, Jean H. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) :1332-1339
[8]   INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY [J].
SHROUT, PE ;
FLEISS, JL .
PSYCHOLOGICAL BULLETIN, 1979, 86 (02) :420-428
[9]   Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T [J].
Yokoo, Takeshi ;
Shiehmorteza, Masoud ;
Hamilton, Gavin ;
Wolfson, Tanya ;
Schroeder, Michael E. ;
Middleton, Michael S. ;
Bydder, Mark ;
Gamst, Anthony C. ;
Kono, Yuko ;
Kuo, Alexander ;
Patton, Heather M. ;
Horgan, Santiago ;
Lavine, Joel E. ;
Schwimmer, Jeffrey B. ;
Sirlin, Claude B. .
RADIOLOGY, 2011, 258 (03) :749-759
[10]   Nonalcoholic Fatty Liver Disease: Diagnostic and Fat-Grading Accuracy of Low-Flip-Angle Multiecho Gradient-Recalled-Echo MR Imaging at 1.5 T [J].
Yokoo, Takeshi ;
Bydder, Mark ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Gamst, Anthony C. ;
Wolfson, Tanya ;
Hassanein, Tarek ;
Patton, Heather M. ;
Lavine, Joel E. ;
Schwimmer, Jeffrey B. ;
Sirlin, Claude B. .
RADIOLOGY, 2009, 251 (01) :67-76