The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [41] USEFULNESS OF SIZE-SPECIFIC DOSE ESTIMATES IN PEDIATRIC COMPUTED TOMOGRAPHY: REVALIDATION OF LARGE-SCALE PEDIATRIC CT DOSE SURVEY DATA IN JAPAN
    Yamazaki, Daisuke
    Miyazaki, Osamu
    Takei, Yasutaka
    Matsubara, Kosuke
    Shinozaki, Masafumi
    Shimada, Yoshiya
    Suzuki, Shoichi
    Muramatsu, Yoshihisa
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 254 - 262
  • [42] Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
    El Mansouri, M'hamed
    Choukri, Abdelmajid
    Semghouli, Slimane
    Talbi, Mohammed
    Eddaoui, Khalida
    Saga, Zouhir
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1648 - 1653
  • [43] Influence of 320-detector-row volume scanning and AAPM report 111 CT dosimetry metrics on size-specific dose estimate: a Monte Carlo study
    Haba, Tomonobu
    Koyama, Shuji
    Kinomura, Yutaka
    Ida, Yoshihiro
    Kobayashi, Masanao
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (03) : 697 - 703
  • [44] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766
  • [45] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158
  • [46] Evaluation of patients' Body Mass Index and weight as a simpler alternative method for calculating size-specific dose estimation in patients with lung computed tomography
    Azinkhah, I.
    Sadeghi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (02): : 257 - 264
  • [47] Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation
    Brady, Samuel L.
    Kaufman, Robert A.
    RADIOLOGY, 2012, 265 (03) : 832 - 840
  • [48] Comparison of methods to estimate water-equivalent diameter for calculation of patient dose
    Daudelin, Andrew
    Medich, David
    Andrabi, Syed Yasir
    Martel, Chris
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 718 - 723
  • [49] Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations
    Alikhani, Babak
    Getzin, Tobias
    Kaireit, Till Frederik
    Ringe, Kristina Imeen
    Jamali, Leila
    Wacker, Frank
    Werncke, Thomas
    Raatschen, Hans-Juergen
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 : 130 - 134
  • [50] Determination of appropriate conversion factors for calculating size-specific dose estimates based on X-ray CT scout images after miscentering correction
    Terashima, Marin
    Mizonobe, Kazufusa
    Date, Hiroyuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (03) : 283 - 289