The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [31] Size-specific dose estimates in chest, abdomen, and pelvis CT examinations of pediatric patients
    Ozsoykal, Ismail
    Yurt, Aysegul
    Akgungor, Kadir
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (04): : 243 - 248
  • [32] Automated size-specific CT dose monitoring program: Assessing variability in CT dose
    Christianson, Olav
    Li, Xiang
    Frush, Donald
    Samei, Ehsan
    MEDICAL PHYSICS, 2012, 39 (11) : 7131 - 7139
  • [33] Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter
    Leng, Shuai
    Shiung, Maria
    Duan, Xinhui
    Yu, Lifeng
    Zhang, Yi
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 276 (01) : 184 - 190
  • [34] Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia
    Kayun, Zunaide
    Karim, Muhammad Khalis Abdul
    Harun, Hanif Haspi
    Shaari, Abdul Halim
    Mahmud, Rozi
    Hamid, Hamzaini Abdul
    Sabarudin, Akmal
    Chew, Ming Tsuey
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [35] The dosimetric impact of including the patient table in CT dose estimates
    Nowik, Patrik
    Bujila, Robert
    Kull, Love
    Andersson, Jonas
    Poludniowski, Gavin
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : N538 - N547
  • [36] Advancing size-specific dose estimates in CT examinations: Dose estimates at longitudinal positions of scans
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2022, 49 (02) : 1303 - 1311
  • [37] Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential
    McCollough, Cynthia H.
    McCollough, Shannon L.
    Schneider, Justine J.
    Moen, Taylor R.
    Weaver, Jayse M.
    Vrieze, Thomas J.
    Yu, Lifeng
    Leng, Shuai
    RADIOLOGY, 2022, 303 (02)
  • [38] Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy
    Martin, C. J.
    Abuhaimed, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [39] Automated size-specific dose estimates using deep learning image processing
    Juszczyk, Jan
    Badura, Pawel
    Czajkowska, Joanna
    Wijata, Agata
    Anderzejewski, Jacek
    Bozek, Pawel
    Smolinski, Michal
    Biesok, Marta
    Sage, Agata
    Rudzki, Marcin
    Wieclawek, Wojciech
    MEDICAL IMAGE ANALYSIS, 2021, 68
  • [40] Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Chris
    Zankl, Maria
    Sepahdari, Ali R.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2014, 41 (12)