The impact of patient table on size-specific dose estimate (SSDE)

被引:28
|
作者
Anam, Choirul [1 ,2 ]
Haryanto, Freddy [2 ]
Widita, Rena [2 ]
Arif, Idam [2 ]
Dougherty, Geoff [3 ]
McLean, Donald [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Semarang 50275, Central Java, Indonesia
[2] Bandung Inst Technol, Dept Phys, Fac Math & Nat Sci, Ganesha 10, Bandung 40132, West Java, Indonesia
[3] CSUCI, Appl Phys & Med Imaging, Camarillo, CA 93012 USA
[4] Canberra Hosp, Med Phys & Radiat Engn, Garran, ACT 2605, Australia
关键词
Water equivalent diameter (D-W); Size-specific dose estimates (SSDE); Volume CT dose index (CTDIVOL); Patient dose; Patient table; ATTENUATION-BASED ESTIMATION; RAY COMPUTED-TOMOGRAPHY; PEDIATRIC CHEST CT; INDEX; IMPLEMENTATION; DIAMETER; MEDICINE; PURPOSE; CANCER; RISKS;
D O I
10.1007/s13246-016-0497-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of parameters water equivalent diameter (D-W) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D-W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D-W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D-W,D- t) is greater, compared to that without the consideration of the patient table (D-W,D- nt), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D-W and SSDE in the thorax CT examination was statistically significant, but its effect on D-W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [1] The impact of patient table on size-specific dose estimate (SSDE)
    Choirul Anam
    Freddy Haryanto
    Rena Widita
    Idam Arif
    Geoff Dougherty
    Donald McLean
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 153 - 158
  • [2] THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 313 - 320
  • [3] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Sulemana, Hamza
    Mumuni, Abdul Nashirudeen
    Abubakari, Izre-deen Osman Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [4] A comparison study of size-specific dose estimate calculation methods
    Parikh, Roshni A.
    Wien, Michael A.
    Novak, Ronald D.
    Jordan, David W.
    Klahr, Paul
    Soriano, Stephanie
    Ciancibello, Leslie
    Berlin, Sheila C.
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 56 - 65
  • [5] Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations
    Moore, Bria M.
    Brady, Samuel L.
    Mirro, Amy E.
    Kaufman, Robert A.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [6] Estimation of size-specific dose estimate (SSDE) of CT scans using an effective diameter electron density
    Almuqbil, Khuloud
    Abuhaimed, Abdullah
    Abanomy, Ahmed
    Alashban, Yazeed
    Alhawas, Abdulrahman
    Martin, Colin J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [7] Evaluation of a new predictive equation for automated calculation of size-specific dose estimate (SSDE) in CT imaging
    Osman, N. D.
    Abdulkadir, M. K.
    Shuaib, I. L.
    Nasirudin, R. A.
    RADIOGRAPHY, 2024, 30 (01) : 237 - 244
  • [8] A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [9] Volume computed tomography dose index (CTDIvol) and size-specific dose estimate (SSDE) for tube current modulation (TCM) in CT scanning
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I
    Dougherty, G.
    McLean, D.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (03): : 289 - 297
  • [10] Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice
    Abuhaimed, Abdullah
    Martin, Colin J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 30 - 39