Binocular adaptive optics visual simulator

被引:54
作者
Fernandez, Enrique J. [1 ]
Prieto, Pedro M. [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Ctr Invest Opt & Nanofis CiOyN, E-30071 Murcia, Spain
关键词
LIQUID-CRYSTAL; SENSOR; ABERRATIONS;
D O I
10.1364/OL.34.002628
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A binocular adaptive optics visual simulator is presented. The instrument allows for measuring and manipulating ocular aberrations of the two eyes simultaneously, while the subject performs visual testing under binocular vision. An important feature of the apparatus consists on the use of a single correcting device and wavefront sensor. Aberrations are controlled by means of a liquid-crystal-on-silicon spatial light modulator, where the two pupils of the subject are projected. Aberrations from the two eyes are measured with a single Hartmann-Shack sensor. As an example of the potential of the apparatus for the study of the impact of the eye's aberrations on binocular vision, results of contrast sensitivity after addition of spherical aberration are presented for one subject. Different binocular combinations of spherical aberration were explored. Results suggest complex binocular interactions in the presence of monochromatic aberrations. The technique and the instrument might contribute to the better understanding of binocular vision and to the search for optimized ophthalmic corrections. (C) 2009 Optical Society of America
引用
收藏
页码:2628 / 2630
页数:3
相关论文
共 15 条
[1]  
*AM NAT STAND I, 2004, Z80282004 ANSI
[2]   The human eye is an example of robust optical design [J].
Artal, P ;
Benito, A ;
Tabernero, J .
JOURNAL OF VISION, 2006, 6 (01) :1-7
[3]   Neural compensation for the eye's optical aberrations [J].
Artal, P ;
Chen, L ;
Fernández, EJ ;
Singer, B ;
Manzanera, S ;
Williams, DR .
JOURNAL OF VISION, 2004, 4 (04) :281-287
[4]   SIMULTANEOUS MEASUREMENT OF 2-POINT-SPREAD FUNCTIONS AT DIFFERENT LOCATIONS ACROSS THE HUMAN FOVEA [J].
ARTAL, P ;
NAVARRO, R .
APPLIED OPTICS, 1992, 31 (19) :3646-3656
[5]   MONOCULAR VERSUS BINOCULAR VISUAL ACUITY [J].
CAMPBELL, FW ;
GREEN, DG .
NATURE, 1965, 208 (5006) :191-&
[6]  
Fernández EJ, 2002, J REFRACT SURG, V18, pS634
[7]   Closed-loop adaptive optics in the human eye [J].
Fernández, EJ ;
Iglesias, I ;
Artal, P .
OPTICS LETTERS, 2001, 26 (10) :746-748
[8]   Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator [J].
Fernandez, Enrique J. ;
Prieto, Pedro M. ;
Artal, Pablo .
OPTICS EXPRESS, 2009, 17 (13) :11013-11025
[9]   Binocular Shack-Hartmann sensor for the human eye [J].
Hampson, K. M. ;
Chin, S. S. ;
Mallen, E. A. H. .
JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) :703-716
[10]   Interocular differences in higher-order aberrations on binocular visual performance [J].
Jimenez, Jose R. ;
Castro, Jose J. ;
Jimenez, Raimundo ;
Hita, Enrique .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (03) :174-179