Assessment of distribution of ventilation by electrical impedance tomography in standing horses

被引:30
作者
Ambrisko, T. D. [1 ]
Schramel, J. P. [1 ]
Adler, A. [2 ]
Kutasi, O. [4 ]
Makra, Z. [3 ]
Moens, Y. P. S. [1 ]
机构
[1] Univ Vet Med, Dept Compan Anim & Horses, Anaesthesiol & Perioperat Intens Care Med, Vienna, Austria
[2] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
[3] Szent Istvan Univ, Fac Vet Sci, Equine Dept & Clin, Ullo, Hungary
[4] Szent Istvan Univ, Large Anim Clin Res Grp, Hungarian Acad Sci, Ullo, Hungary
关键词
distribution of ventilation; electrical impedance tomography; horse; respiration; REGIONAL LUNG VENTILATION; PERFUSION RELATIONSHIPS; VALIDATION; VOLUMES; EIT;
D O I
10.1088/0967-3334/37/2/175
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim was to evaluate the feasibility of using electrical impedance tomography (EIT) in horses. Thoracic EIT was used in nine horses. Thoracic and abdominal circumference changes were also measured with respiratory ultrasound plethysmography (RUP). Data were recorded during baseline, rebreathing of CO2 and sedation. Three breaths were selected for analysis from each recording. During baseline breathing, horses regularly took single large breaths (sighs), which were also analysed. Functional EIT images were created using standard deviations (SD) of pixel signals and correlation coefficients (R) of each pixel signal with a reference respiratory signal. Left-to-right ratio, centre-of-ventilation and global-inhomogeneity-index were calculated. RM-ANOVA and Bonferroni tests were used (P < 0.05). Distribution of ventilation shifted towards right during sighs and towards dependent regions during sighs, rebreathing and sedation. Global-inhomogeneity-index did not change for SD but increased for R images during sedation. The sum of SDs for the respiratory EIT signals correlated well with thoracic (r(2) = 0.78) and abdominal (r(2) = 0.82) tidal circumferential changes. Inverse respiratory signals were identified on the images at sternal location and based on reviewing CT images, seemed to correspond to location of gas filled intestines. Application of EIT in standing non-sedated horses is feasible. EIT images may provide physiologically useful information even in situations, such as sighs, that cannot easily be tested by other methods.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 40 条
[1]   Impedance imaging of lung ventilation: Do we need to account for chest expansion? [J].
Adler, A ;
Guardo, R ;
Berthiaume, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) :414-420
[2]   Whither lung EIT: Where are we, where do we want to go and what do we need to get there? [J].
Adler, Andy ;
Amato, Marcelo B. ;
Arnold, John H. ;
Bayford, Richard ;
Bodenstein, Marc ;
Boehm, Stephan H. ;
Brown, Brian H. ;
Frerichs, Inez ;
Stenqvist, Ola ;
Weiler, Norbert ;
Wolf, Gerhard K. .
PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) :679-694
[3]   GREIT: a unified approach to 2D linear EIT reconstruction of lung images [J].
Adler, Andy ;
Arnold, John H. ;
Bayford, Richard ;
Borsic, Andrea ;
Brown, Brian ;
Dixon, Paul ;
Faes, Theo J. C. ;
Frerichs, Inez ;
Gagnon, Herve ;
Gaerber, Yvo ;
Grychtol, Bartlomiej ;
Hahn, Guenter ;
Lionheart, William R. B. ;
Malik, Anjum ;
Patterson, Robert P. ;
Stocks, Janet ;
Tizzard, Andrew ;
Weiler, Norbert ;
Wolf, Gerhard K. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) :S35-S55
[4]  
AMIS TC, 1984, AM J VET RES, V45, P1597
[5]  
Corley K, 2008, EQUINE HOSP MANUAL, P681
[6]   Real-time detection of pneumothorax using electrical impedance tomogyaphy [J].
Costa, Eduardo L. V. ;
Chaves, Caroline N. ;
Gomes, Susimeire ;
Beraldo, Marcelo A. ;
Volpe, Marcia S. ;
Tucci, Mauro R. ;
Schettino, Lvany A. L. ;
Bohm, Stephan H. ;
Carvalho, Carlos R. R. ;
Tanaka, Harki ;
Lima, Raul G. ;
Amato, Marcelo B. P. .
CRITICAL CARE MEDICINE, 2008, 36 (04) :1230-1238
[7]   Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography [J].
Costa, Eduardo L. V. ;
Borges, Joao Batista ;
Melo, Alexandre ;
Suarez-Sipmann, Fernando ;
Toufen, Carlos, Jr. ;
Bohm, Stephan H. ;
Amato, Marcelo B. P. .
INTENSIVE CARE MEDICINE, 2009, 35 (06) :1132-1137
[8]   Electrical impedance tomography [J].
Costa, Eduardo L. V. ;
Lima, Raul Gonzalez ;
Amato, Marcelo B. P. .
CURRENT OPINION IN CRITICAL CARE, 2009, 15 (01) :18-24
[9]  
Couëtil LL, 2007, J VET INTERN MED, V21, P356, DOI 10.1892/0891-6640(2007)21[356:IADOH]2.0.CO
[10]  
2