First Evaluation of a Retinal Imaging Laser Eyewear System Based Low Vision Aid

被引:4
作者
Stoehr, Mareile [1 ]
Dekowski, Dirk [1 ]
Bechrakis, Nikolaos [1 ]
Esser, Joachim [1 ]
Eckstein, Anja [1 ]
Oeverhaus, Michael [1 ]
机构
[1] Univ Hosp Essen, Dept Ophthalmol, Hufelandstr 55, D-45147 Essen, Germany
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
low vision; visual impairment; VI; corneal haze; visual rehabilitation; dystrophy; low vision aid; LVA; Maxwellian view; augmented reality; AR; VIRTUAL-REALITY; READING PERFORMANCE; SCANNING DISPLAY; VISUAL-ACUITY; DESIGN; SPEED; TEXTS;
D O I
10.2147/OPTH.S273810
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We conducted this trial to investigate a new wearable laser-eyewear (LEW). Images of an integrated camera are projected to the retina by a RGB-Laser (<1 mu W) and MEMS-mirror system. This enables a full-color live video as augmented reality embedded in the field of vision of the wearer. Thin parallel laser beams are projected following the principle of Maxwellian view through the center of the ocular lens to ensure independency of refractive errors. We performed a study with healthy subjects to test this independency. Materials and Methods: LEW was tested in 20 healthy subjects (aged between 21 and 60 years) with hyperopia, myopia, astigmatism and/or presbyopia. Subjects underwent standardized visual acuity (VA) measurements (ETDRS) without any correction, with LEW and with best correction. Results: We found no significant correlation between refraction and VA while using LEW in linear regression (r=0.17). Still, younger participants performed better in terms of VA with the device compared to older participants despite no differences in BCVA (p<0.01). The achievable VA with LEW was in general reduced compared to uncorrected VA (0.50 vs 0.40 logMAR). Only myopic subjects reached a significantly higher VA using LEW (p<0.001). Presbyopic subjects showed enhanced near VA (0.25 logMAR) by reading at 15cm with LEW without any further necessary refractive correction. Nearly all patients (80%) showed stereopsis without need for additional adjustments. Conclusion: Our investigation could verify the independence of LEW of refractive errors. Therefore, the technology seems to be especially useful in patients with untreatable corneal conditions, e.g., after corneal burns, to achieve higher VA since the thin laser should penetrate even corneal opacities with less scattering.
引用
收藏
页码:4115 / 4123
页数:9
相关论文
共 32 条
[1]  
BAILEY IL, 1980, AM J OPTOM PHYS OPT, V57, P378
[2]   Optical reading aids for children and young people with low vision [J].
Barker, Lucy ;
Thomas, Rachel ;
Rubin, Gary ;
Dahlmann-Noor, Annegret .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (03)
[3]   Depression, visual acuity, comorbidity, and disability associated with age-related macular degeneration [J].
Brody, BL ;
Gamst, AC ;
Williams, RA ;
Smith, AR ;
Lau, PW ;
Dolnak, D ;
Rapaport, MH ;
Kaplan, RM ;
Brown, SI .
OPHTHALMOLOGY, 2001, 108 (10) :1893-1900
[4]   Fusional movements - Role of peripheral retinal stimuli [J].
Burian, HM .
ARCHIVES OF OPHTHALMOLOGY, 1939, 21 (03) :486-491
[5]   Design of foveated contact lens display for augmented reality [J].
Chen, Jie ;
Mi, Lantian ;
Chen, Chao Ping ;
Liu, Haowen ;
Jiang, Jinghui ;
Zhang, Wenbo .
OPTICS EXPRESS, 2019, 27 (26) :38204-38219
[6]  
Crone R A, 1978, Buch Augenarzt, V72, P49
[7]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[8]   New standardised texts for assessing reading performance in four European languages [J].
Hahn, GA ;
Penka, D ;
Gehrlich, C ;
Messias, A ;
Weismann, M ;
Hyvärinen, L ;
Leinonen, M ;
Feely, M ;
Rubin, G ;
Dauxerre, C ;
Vital-Durand, F ;
Featherston, S ;
Dietz, K ;
Trauzettel-Klosinski, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (04) :480-484
[9]   QD laser eyewear as a visual field aid in a visual field defect model [J].
Iyama, Chigusa ;
Shigeno, Yuta ;
Hirano, Eri ;
Kamoshita, Mamoru ;
Nagai, Norihiro ;
Suzuki, Misa ;
Minami, Sakiko ;
Kurihara, Toshihide ;
Sonobe, Hideki ;
Watanabe, Kazuhiro ;
Shinoda, Hajime ;
Tsubota, Kazuo ;
Ozawa, Yoko .
SCIENTIFIC REPORTS, 2019, 9 (1)
[10]  
Kleweno CP, 2001, J REHABIL RES DEV, V38, P431