Surface finishing of biodegradable stents

被引:9
作者
Yamaguchi, Hitomi [1 ]
Li, Mingshuo [1 ]
Hanada, Kotaro [2 ]
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, 226 MAE B, Gainesville, FL 32611 USA
[2] Natl Inst Adv Ind Sci & Technol, Adv Mfg Res Inst, 1-2-1 Namiki, Tsukuba, Ibaraki, Japan
关键词
Polishing; Roughness; Surface integrity; MAGNESIUM ALLOYS; PERFORMANCE;
D O I
10.1016/j.cirp.2019.04.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The surface conditions of stents influence their polymer/drug coatability, rate of degradation, and ultimately their mechanical strength, ability to expand, and service lifetime. This paper describes new polishing tools developed to mechanically polish entire biodegradable magnesium-alloy stents. Use of the new tools removes material from the peaks of the stent surfaces and enables surface smoothing equivalent to electrolytic polishing (EP) but with less material removal, helping extend the stent service life. Static immersion tests using Dulbecco's modification of Eagle medium solution demonstrated that stents polished using the new tools had a rate of degradation about 40% lower than EP-processed stents. (C) 2019 Published by Elsevier Ltd on behalf of CIRP.
引用
收藏
页码:357 / 360
页数:4
相关论文
共 15 条
[1]   Large strain extrusion machining of magnesium alloys for biomedical applications [J].
Bertolini, R. ;
Bruschi, S. ;
Ghiotti, A. ;
Pezzato, L. ;
Dabala, M. .
4TH CIRP CONFERENCE ON SURFACE INTEGRITY (CSI 2018), 2018, 71 :105-110
[2]   Machining-induced surface transformations of magnesium alloys to enhance corrosion resistance in human-like environment [J].
Bruschi, Stefania ;
Bertolini, Rachele ;
Ghiotti, Andrea ;
Savio, Enrico ;
Guo, Wei ;
Shivpuri, Rajiv .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2018, 67 (01) :579-582
[3]   Biocompatible magnesium alloys as absorbable implant materials - Adjusted surface and subsurface properties by machining processes [J].
Denkena, B. ;
Lucas, A. .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2007, 56 (01) :113-116
[4]  
Du X, 2015, P INT C LEAD EDG MAN
[5]   The Effect of Surface Treatments on the Degradation of Biomedical Mg Alloys-A Review Paper [J].
Gawlik, Marcjanna Maria ;
Wiese, Bjoern ;
Desharnais, Valerie ;
Ebel, Thomas ;
Willumeit-Roemer, Regine .
MATERIALS, 2018, 11 (12)
[6]   Effect of laser shock peening on the stress corrosion cracking of AZ31B magnesium alloy in a simulated body fluid [J].
Ge, Mao-Zhong ;
Xiang, Jian-Yun ;
Yang, L. ;
Wang, J. T. .
SURFACE & COATINGS TECHNOLOGY, 2017, 310 :157-165
[7]   Fabrication of Mg alloy tubes for biodegradable stent application [J].
Hanada, Kotaro ;
Matsuzaki, Kunio ;
Huang, Xinsheng ;
Chino, Yasumasa .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08) :4746-4750
[8]   Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial [J].
Haude, Michael ;
Ince, Hueseyin ;
Abizaid, Alexandre ;
Toelg, Ralph ;
Lemos, Pedro Alves ;
von Birgelen, Clemens ;
Christiansen, Evald Hoj ;
Wijns, William ;
Neumann, Franz-Josef ;
Kaiser, Christoph ;
Eeckhout, Eric ;
Teik Lim, Soo ;
Escaned, Javier ;
Garcia-Garcia, Hector M. ;
Waksman, Ron .
LANCET, 2016, 387 (10013) :31-39
[9]   Biodegradable stents for coronary artery disease treatment: Recent advances and future perspectives [J].
Hu, Tingzhang ;
Yang, Chun ;
Lin, Song ;
Yu, Qingsong ;
Wang, Guixue .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 91 :163-178
[10]   Biodegradable coronary scaffolds: their future and clinical and technological challenges [J].
Hytonen, Jarkko P. ;
Taavitsainen, Jouni ;
Tarvainen, Santeri ;
Yla-Herttuala, Seppo .
CARDIOVASCULAR RESEARCH, 2018, 114 (08) :1063-1072