Combined imaging system for X-ray fluorescence and transmission X-ray microtomography

被引:3
作者
Ohigashi, T [1 ]
Watanabe, N [1 ]
Yokosuka, H [1 ]
Aoki, S [1 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
来源
SYNCHROTRON RADIATION INSTRUMENTATION | 2004年 / 705卷
关键词
D O I
10.1063/1.1758052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A full-field imaging x-ray fluorescence computed microtomography system was designed for quantitative elemental analysis. An x-ray fluorescence imaging microscope combined with transmission x-ray microtomographic system was constructed at BL3C2 of the Photon Factory, KEK, Japan. The quasi-monochromatic beam produced by a double-multilayer monochromator was used as an incident beam. X-ray fluorescence images were obtained and were reconstructed by simultaneous algebraic reconstruction technique (SART) with taking into account of the self-absorption effects of the incident beam and the x-ray fluorescence of the sample. Distribution of Fe in a standard sample (1.60 mol/l FeCl2 solution in a capillary tube) was observed to evaluate the system. The density of Fe reconstructed without correction of the self-absorption effect was 9.26 % of the actual density. Using this correction method, 73.0 % of the actual density could be obtained.
引用
收藏
页码:1352 / 1355
页数:4
相关论文
共 7 条
[1]   Quantitative characterization of microsamples by x-ray fluorescence tomography [J].
Chukalina, M ;
Simionovici, A ;
Snigirev, A ;
Jeffries, T .
X-RAY SPECTROMETRY, 2002, 31 (06) :448-450
[2]  
Kak A.C., 2001, PRINCIPLES COMPUTERI, P275, DOI [DOI 10.1137/1.9780898719277, DOI 10.1137/1.9780898719277.CH7]
[3]  
OHIGASHI T, 2003, 7 INT C XRAY MICR 20, P53
[4]   X-ray fluorescent computer tomography with synchrotron radiation [J].
Rust, GF ;
Weigelt, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (01) :75-88
[5]   Reconstructing x-ray fluorescence microtomograms [J].
Schroer, CG .
APPLIED PHYSICS LETTERS, 2001, 79 (12) :1912-1914
[6]   X-ray fluorescence microtomography with a Wolter mirror system [J].
Watanabe, N ;
Yamamoto, K ;
Takano, H ;
Ohigashi, T ;
Yokosuka, H ;
Aota, T ;
Aoki, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :837-840
[7]   Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition [J].
Yuasa, T ;
Akiba, M ;
Takeda, T ;
Kazama, M ;
Hoshino, A ;
Watanabe, Y ;
Hyodo, K ;
Dilmanian, FA ;
Akatsuka, T ;
Itai, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) :54-62