Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening

被引:98
作者
Sun, Tao [1 ]
Samiotaki, Gesthimani [1 ]
Wang, Shutao [1 ]
Acosta, Camilo [1 ]
Chen, Cherry C. [1 ]
Konofagou, Elisa E. [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY USA
[2] Columbia Univ, Dept Radiol, New York, NY USA
关键词
acoustic cavitation; treatment monitoring; blood-brain barrier; drug delivery; passive cavitation detection; microbubble; focused ultrasound; GUIDED FOCUSED ULTRASOUND; TARGETED DRUG-DELIVERY; IN-VIVO; CONTRAST MICROBUBBLES; ADENOASSOCIATED VIRUS; ENHANCED DELIVERY; DISRUPTION; DEPENDENCE; MRI; PRESSURE;
D O I
10.1088/0031-9155/60/23/9079
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cavitation events seeded by microbubbles have been previously reported to be associated with MR- or fluorescent-contrast enhancement after focused ultrasound (FUS)-induced blood-brain barrier (BBB) opening. However, it is still unknown whether bubble activity can be correlated with the reversibility (the duration of opening and the likelihood of safe reinstatement) and the permeability of opened BBB, which is critical for the clinical translation of using passive cavitation detection to monitor, predict and control the opening. In this study, the dependence of acoustic cavitation on the BBB opening duration, permeability coefficient and histological damage occurrence were thus investigated. Transcranial pulsed FUS at 1.5 MHz in the presence of systemically circulating microbubbles was applied in the mouse hippocampi (n = 60). The stable and inertial cavitation activities were monitored during sonication. Contrast-enhanced MRI was performed immediately after sonication and every 24 h up to 6 d thereafter, to assess BBB opening, brain tissue permeability and potential edema. Histological evaluations were used to assess the occurrence of neurovascular damages. It was found that stable cavitation was well correlated with: (1) the duration of the BBB opening (r(2) = 0.77); (2) the permeability of the opened BBB (r(2) = 0.82); (3) the likelihood of safe opening (P < 0.05, safe opening compared to cases of damage; P < 0.0001, no opening compared to safe opening). The inertial cavitation dose was correlated with the resulting BBB permeability (r(2) = 0.72). Stable cavitation was found to be more reliable than inertial cavitation at assessing the BBB opening within the pressure range used in this study. This study demonstrates that the stable cavitation response during BBB opening holds promise for predicting and controlling the restoration and pharmacokinetics of FUS-opened BBB. The stable cavitation response therefore showed great promise in predicting the BBB opening duration, enabling thus control of opening according to the drug circulation time. In addition, avoiding adverse effects in the brain and assessing the pharmacokinetics of the compounds delivered can also be achieved by monitoring and controlling the stable cavitation emissions.
引用
收藏
页码:9079 / 9094
页数:16
相关论文
共 40 条
[1]   Review of scattering and extinction cross-sections, damping factors, and resonance frequencies of a spherical gas bubble [J].
Ainslie, Michael A. ;
Leighton, Timothy G. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (05) :3184-3208
[2]  
American Institute of Ultrasound in Medicine, 2000, J ULTRAS MED, V19, P97
[3]   Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain [J].
Arvanitis, Costas D. ;
Livingstone, Margaret S. ;
McDannold, Nathan .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14) :4749-4761
[4]   Controlled Ultrasound-Induced Blood-Brain Barrier Disruption Using Passive Acoustic Emissions Monitoring [J].
Arvanitis, Costas D. ;
Livingstone, Margaret S. ;
Vykhodtseva, Natalia ;
McDannold, Nathan .
PLOS ONE, 2012, 7 (09)
[5]   Ultrasound-mediated blood-brain barrier disruption for targeted drug delivery in the central nervous system [J].
Aryal, Muna ;
Arvanitis, Costas D. ;
Alexander, Phillip M. ;
McDannold, Nathan .
ADVANCED DRUG DELIVERY REVIEWS, 2014, 72 :94-109
[6]   Gauging the likelihood of stable cavitation from ultrasound contrast agents [J].
Bader, Kenneth B. ;
Holland, Christy K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :127-144
[7]   Noninvasive and Targeted Drug Delivery to the Brain Using Focused Ultrasound [J].
Burgess, Alison ;
Hynynen, Kullervo .
ACS CHEMICAL NEUROSCIENCE, 2013, 4 (04) :519-526
[8]   A New Brain Drug Delivery Strategy: Focused Ultrasound-Enhanced Intranasal Drug Delivery [J].
Chen, Hong ;
Chen, Cherry C. ;
Acosta, Camilo ;
Wu, Shih-Ying ;
Sun, Tao ;
Konofagou, Elisa E. .
PLOS ONE, 2014, 9 (10)
[9]   The size of blood-brain barrier opening induced by focused ultrasound is dictated by the acoustic pressure [J].
Chen, Hong ;
Konofagou, Elisa E. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (07) :1197-1204
[10]   Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice [J].
Choi, James J. ;
Pernot, Mathieu ;
Small, Scott A. ;
Konofagou, Elisa E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01) :95-104