A review of non-standard artificial contamination withstand test methods of composite insulators

被引:0
|
作者
Mohseni, H [1 ]
Sanaye-Pasand, M [1 ]
Naderian, A [1 ]
机构
[1] Univ Tehran, High Voltage Lab, Fac Engn, Tehran, Iran
来源
PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2 | 2004年
关键词
D O I
暂无
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
Though many electric companies have used composite insulators (CI) for many years and there are several recommendation for their properties, there is not a universe standard for artificial contamination test of non-ceramic insulators. This paper reviews some of major non-standard pollution test methods for CI. Salt fog method cannot give consistent results with actual field results. Clean Fog test with a suitable precontamination can give better result. Besides the contamination methods, the artificial rain test for contaminated CI is also should be considered to evaluate them.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [1] A review of artificial contamination withstand test methods of high voltage outdoor insulators
    Naderian, A
    Sanaye-Pasand, M
    Mohseni, H
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 284 - 287
  • [2] An artificial contamination method for composite insulators
    Besztercey, G
    Karady, GG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 732 - 737
  • [3] Comparison of on-load voltage methods in artificial contamination test for insulators
    Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
    不详
    不详
    Zhang, C. (zcy615@foxmail.com), 2013, Science Press (39):
  • [4] Solving methods for non-standard problems
    Kudusov, A. S.
    Musenova, E. K.
    BULLETIN OF THE UNIVERSITY OF KARAGANDA-PHYSICS, 2012, 3 (67): : 72 - 77
  • [5] STANDARD AND NON-STANDARD LIGHTNING PROTECTION METHODS.
    Mackerras, D.
    Darveniza, M.
    Liew, A.C.
    Journal of Electrical and Electronics Engineering, Australia, 1987, 7 (02): : 133 - 140
  • [6] A non-standard view on artificial neural networks
    Vracko, Marjan
    Zupan, Jure
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 149 : 140 - 152
  • [7] A COMPARISON OF CONTAMINATION TEST METHODS FOR DC LINE INSULATORS
    PARGAMIN, L
    TARTIER, S
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (03): : 224 - 230
  • [8] Study on Artificial Contamination Test of Typical Transmission Line Insulators
    Gu, Chunhui
    Lu, Guojun
    Yi, Mancheng
    Li, Jiangtao
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1624 - 1627
  • [9] Models for the longitudinal shear resistance of composite slabs, and the use of non-standard test data
    Johnson, Roger P.
    Composite Construction in Steel and Concrete V, 2006, : 157 - 165
  • [10] Polynomial time uniformization and non-standard methods
    Ressayre, JP
    ANNALS OF MATHEMATICS AND ARTIFICIAL INTELLIGENCE, 1996, 16 (1-4) : 75 - 88