A comprehensive sensitivity study of major passive design parameters for the public rental housing development in Hong Kong

被引:44
作者
Chen, Xi [1 ]
Yang, Hongxing [1 ]
Zhang, Weilong [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, RERG, Kowloon, Hong Kong, Peoples R China
关键词
Mixed-mode ventilation; Thermal comfort; Passive design; Energy saving; Sensitivity analysis; RESIDENTIAL BUILDINGS; NATURAL-VENTILATION; APARTMENT BUILDINGS; ENERGY PERFORMANCE; OFFICE BUILDINGS; THERMAL COMFORT; REQUIREMENTS; SIMULATION; CONSUMPTION; CLIMATES;
D O I
10.1016/j.energy.2015.10.061
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a comprehensive SA (sensitivity analysis) of the typical PRH (public rental housing) development in Hong Kong based on a combined building energy, daylight and AFN (airflow network) simulation. A generic building model is constructed with a proposed MM (mixed-mode) ventilation control strategy to fulfill the thermal comfort requirement in the local green building guidance. The numerical modeling results are used to conduct both local and global sensitivity analyses to determine the relative importance of major passive design parameters, which comprehensively cover design aspects of the building layout, envelop thermophysics, building geometry and infiltration & air-tightness. The calculated global and local sensitivity indices on the cooling energy prove that the window solar heat gain coefficient, window to ground ratio, external obstruction and overhang projection fraction are the four most influential passive design factors. Similar results are also obtained when the lighting energy is specified as the output of the sensitivity analysis. The optimized building model derived from the sensitivity analysis is anticipated to achieve an energy saving of 41.6% compared to the baseline model as stipulated by the local building regulation. It is believed that sensitivity analysis is useful for identifying crucial design parameters to facilitate further optimization of the building performance in early architectural design stages. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1804 / 1818
页数:15
相关论文
共 39 条
  • [1] [Anonymous], 2002, SPSS SURVIVAL MANUAL
  • [2] [Anonymous], 2012, BEAM PLUS ASS FLOW C
  • [3] [Anonymous], 2013, EnergyPlus engineering reference: the reference to EnergyPlus calculations
  • [4] [Anonymous], WHOLE LIFE VALUE OPT
  • [5] Warm season cooling requirements for passive buildings in Southeastern Europe (Romania)
    Badescu, Viorel
    Laaser, Nadine
    Crutescu, Ruxandra
    [J]. ENERGY, 2010, 35 (08) : 3284 - 3300
  • [6] Sensitivity analysis of the effect of occupant behaviour on the energy consumption of passive house dwellings
    Blight, Thomas S.
    Coley, David A.
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 183 - 192
  • [7] Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis
    Breesch, H.
    Janssens, A.
    [J]. SOLAR ENERGY, 2010, 84 (08) : 1453 - 1467
  • [8] Uncertainties and sensitivity analysis in building energy simulation using macroparameters
    Calleja Rodriguez, Gloria
    Carrillo Andres, Antonio
    Dominguez Munoz, Fernando
    Cejudo Lopez, Jose Manuel
    Zhang, Yi
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 79 - 87
  • [9] Census and Statistics Department, 2007, POP TYP HOUS
  • [10] Census and Statistics Department, 2013, HONG KONG EN STAT AN