Robustness of Prefabricated Prefinished Volumetric Construction (PPVC) High-rise Building

被引:25
作者
Chua, Y. S. [1 ]
Liew, J. Y. R. [1 ,2 ]
Pang, S. D. [1 ]
机构
[1] Natl Univ Singapore, Dept Civil & Environm Engn, Singapore, Singapore
[2] Nanjing Tech Univ, Coll Civil Engn, Nanjing, Jiangsu, Peoples R China
来源
PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018) | 2018年
基金
新加坡国家研究基金会;
关键词
Modular; High-rise; Robustness; Column removal; Pushdown; PROGRESSIVE COLLAPSE; COLUMN LOSS; FRAMES;
D O I
10.4995/ASCCS2018.2018.6955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the safety awareness arisen from natural and human-caused disasters, robustness design of building is increasingly important to ensure the stability of the building and to prevent progressive collapse. For this reason, the robustness design of innovative construction technologies such as modular construction may be essential due to its relative novel structural form and numerous joints among modules. Particularly in Singapore, Prefabricated Prefinished Volumetric Construction ( PPVC) has been highly promoted in residential and commercial buildings, hostels and hospitals to boost the construction productivity and quality as well as to reduce the reliance on foreign workforce. PPVC offers high quality and efficiency because most of the finishes and mechanical and electrical services are manufactured and installed together with the modules in factory, before sending for on-site assembly. To maximize the productivity of PPVC, modular design standardization and repetition can be improved by going for high-rise. Nonetheless, there are limited studies on the robustness of PPVC high-rise building and its behavior under progressive collapse remains uncertain. Therefore, this paper investigates the robustness of steel PPVC high-rise building under column removal scenarios by conducting non-linear numerical analysis. The effects of joint design and diaphragm action between modules are studied to ensure continuity of horizontal and vertical tying. This paper provides insight on the behaviour and alternative path for load transfer under column removal scenario for future design guideline of robustness PPVC building.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 15 条
  • [1] [Anonymous], 2005, DES STEEL STRUCT
  • [2] [Anonymous], 2016, Seismic Design of Buildings to Eurocode 8
  • [3] British Standards Institution (BSI), 2014, 19911172006A12014 BS
  • [4] DoD, 2009, UN FAC CRIT UFC DES
  • [5] Federal Emergency Management Agency, 2000, 356 FEMA
  • [6] GSA, 2013, GSA ALT PATH AN DES
  • [7] Progressive collapse of multi-storey buildings due to sudden column loss - Part I: Simplified assessment framework
    Izzuddin, B. A.
    Vlassis, A. G.
    Elghazouli, A. Y.
    Nethercot, D. A.
    [J]. ENGINEERING STRUCTURES, 2008, 30 (05) : 1308 - 1318
  • [8] Assessment of progressive collapse in multi-storey buildings
    Izzuddin, B. A.
    Vlassis, A. G.
    Elghazouli, A. Y.
    Nethercot, D. A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2007, 160 (04) : 197 - 205
  • [9] Plastic Hinge Analysis of Composite Frames under Column Loss Scenario
    Jeyarajan, S.
    Liew, J. Y. Richard
    Koh, C. G.
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (03) : 975 - 985
  • [10] Enhancing the Robustness of Steel-Concrete Composite Buildings under Column Loss Scenarios
    Jeyarajan, S.
    Liew, J. Y. Richard
    Koh, C. G.
    [J]. INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2015, 6 (03) : 529 - 550