Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography

被引:4
作者
Oh, Eunsun [1 ]
Yoon, Young C. [1 ]
Park, Min J. [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiol, Samsung Med Ctr, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Orthoped Surg, Samsung Med Ctr, Seoul, South Korea
关键词
3.0; T; TRIANGULAR FIBROCARTILAGE; STANDARD MRI; TFCC TEARS; TESLA; SHOULDER; KNEE; LIGAMENTS; ARTHROSCOPY; EXPERIENCE;
D O I
10.1259/bjr.20160867
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of direct wrist MR arthrography (D-MRA) with two-dimensional (2D) T-1 weighted fast spin-echo (FSE) and three-dimensional (3D) isotropic T-1 weighted FSE sequences for detecting triangular fibrocartilage (TFC) central perforations and scapholunate ligament (SLL) and lunotriquetral ligament (LTL) tears. Methods: 26 patients who had undergone pre-operative wrist D-MRA with 2D and 3D isotropic T-1 weighted FSE sequences and subsequent arthroscopic surgeries were included. Each MRI sequence was independently evaluated and scored by two readers retrospectively for the presence of TFC central perforations and SLL and LTL tears. Arthroscopic findings were used as the reference standard. Diagnostic performance was evaluated by using the area under the receiver operating characteristic curve. The sensitivity, specificity and accuracy of both sequences for diagnosing the injuries were calculated. Results: Arthroscopic surgery revealed 21 TFC central perforations, 7 SLL tears and 3 LTL tears. The area under the receiver operating characteristic curve value of 2D and 3D for central perforations in TFC and tears in SLL and LTL was identical or similar (0.667-0.947). The sensitivity, specificity and accuracy of both sequences for diagnosing the injury of each structure were not significantly different (TFC, 90.5/80/88.5% for both readers/sequences; SLL, 100/89.5/92.3% for both readers' 2D and Reader A's 3D, and 85.7/89.5/88.5% for Reader B's 3D; LTL, 66.7/100/96.2% for both readers' 2D and 33.3/100/92.3% for both readers' 3D). Interobserver agreements were substantial to excellent. Conclusion: In wrist D-MRA, the diagnostic performances of 3D isotropic and 2D T-1 weighted FSE sequences are comparable for TFC central perforations and SLL and LTL tears.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Bencardino Jenny T, 2004, Magn Reson Imaging Clin N Am, V12, P333, DOI 10.1016/j.mric.2004.02.010
  • [2] Bordalo-Rodrigues Marcelo, 2004, Magn Reson Imaging Clin N Am, V12, P265, DOI 10.1016/j.mric.2004.02.008
  • [3] Comparison of Three-dimensional Isotropic T1-weighted Fast Spin-Echo MR Arthrography with Two-dimensional MR Arthrography of the Shoulder
    Choo, Hye Jung
    Lee, Sun Joo
    Kim, Ok-Hwoa
    Seo, Seung Suk
    Kim, Jung Han
    [J]. RADIOLOGY, 2012, 262 (03) : 921 - 931
  • [4] Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience
    Gold, Garry E.
    Busse, Reed F.
    Beehler, Carol
    Han, Eric
    Brau, Anja C. S.
    Beatty, Philip J.
    Beaulieu, Christopher F.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1287 - 1293
  • [5] MRI in the diagnosis of cartilage injury in the wrist
    Haims, AH
    Moore, AE
    Schweitzer, ME
    Morrison, WB
    Deely, D
    Culp, RW
    Forman, HP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) : 1267 - 1270
  • [6] Magnetic resonance imaging of the wrist: Diagnostic performance statistics
    Hobby, JL
    Tom, BDM
    Bearcroft, PWP
    Dixon, AK
    [J]. CLINICAL RADIOLOGY, 2001, 56 (01) : 50 - 57
  • [7] Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
    Jung, Jee Young
    Yoon, Young Cheol
    Jung, Jin Young
    Choe, Bong-Keun
    [J]. ACTA RADIOLOGICA, 2013, 54 (03) : 284 - 291
  • [8] Diagnosis of Internal Derangement of the Knee at 3.0-T MR Imaging: 3D Isotropic Intermediate-weighted versus 2D Sequences
    Jung, Jee Young
    Yoon, Young Cheol
    Kwon, Jong Won
    Ahn, Jin Hwan
    Choe, Bong-Keun
    [J]. RADIOLOGY, 2009, 253 (03) : 780 - 787
  • [9] Three-dimensional Isotropic Shoulder MR Arthrography: Comparison with Two-dimensional MR Arthrography for the Diagnosis of Labral Lesions at 3.0 T
    Jung, Jee Young
    Yoon, Young Cheol
    Choi, Sang-Hee
    Kwon, Jong Won
    Yoo, Jaechul
    Choe, Bong-Keun
    [J]. RADIOLOGY, 2009, 250 (02) : 498 - 505
  • [10] Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Y.
    Lee, So-Yeon
    Kim, Yang-Soo
    [J]. SKELETAL RADIOLOGY, 2012, 41 (11) : 1401 - 1410