Experimental study on the thermal behaviour of fire exposed slim-floor beams

被引:0
|
作者
Albero, V [1 ]
Espinos, A. [1 ]
Serra, E. [1 ]
Romero, M. L. [1 ]
Hospitaler, A. [1 ]
机构
[1] Univ Politecn Valencia, ICITECH, Valencia, Spain
来源
PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018) | 2018年
关键词
Composite steel-concrete beams; fire resistance; slim-floors; thermal behaviour;
D O I
10.4995/ASCCS2018.2018.8288
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite beams embedded in floors ( slim-floors) offer various advantages such as the floor thickness reduction or the ease of installation of under-floor technical equipment. However, this typology presents important differences in terms of thermal behaviour, as compared to other composite beams, when exposed to elevated temperatures. These differences are due to their special configuration, being totally contained within the concrete floor depth. Moreover, the current European fire design code for composite steel-concrete structures ( EN 1994-1-2) does not provide any simplified thermal model to evaluate the temperature evolution of each slim-floor part during a fire. Additionally, only a few experimental studies can be found which may help understand the thermal behaviour of these composite beams. This paper presents an experimental investigation on the thermal behaviour of slim-floor beams. Electrical radiative panels were used in the test setup to produce the thermal heating. The thermal gap between the lower flange of the steel profile and the bottom steel plate was studied, being found to be one of the most influential elements over the cross-section temperature gradient. The experimental campaign was developed by varying the cross-section configuration in order to evaluate the influence of this parameter over the slim-floor thermal behavior. Finally, the experiments carried out were used to develop and calibrate a finite element thermal model which may help in further research on the thermal behaviour of slim-floor composite beams.
引用
收藏
页码:819 / 823
页数:5
相关论文
共 50 条
  • [1] Fire design of slim-floor beams
    Romero, Manuel L.
    Albero, Vicente
    Espinos, Ana
    Hospitaler, Antonio
    STAHLBAU, 2019, 88 (07) : 665 - 674
  • [2] Numerical Study of the Fire Behavior of Encased and Slim-Floor Composite Beams
    Wang, Wenjun
    Jiang, Binhui
    Ding, Fa-xing
    Wang, Yong
    Liu, Xue-mei
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2023, 37 (06)
  • [3] Innovative solutions for enhancing the fire resistance of slim-floor beams: Thermal experiments
    Albero, V
    Serra, E.
    Espinos, A.
    Romero, M. L.
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 165
  • [4] Fire behavior and resistance of partially encased and slim-floor composite beams
    Ahn, Jae-Kwon
    Lee, Cheol-Ho
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 129 : 276 - 285
  • [5] Recent developments and fire design provisions for CFST columns and slim-floor beams
    Romero, M. L.
    Espinos, A.
    Lapuebla-Ferri, A.
    Albero, V
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
  • [6] A review on fire resistance of steel-concrete composite slim-floor beams
    Memarzadeh, Armin
    Shahmansouri, Amir Ali
    Nematzadeh, Mahdi
    Gholampour, Aliakbar
    STEEL AND COMPOSITE STRUCTURES, 2021, 40 (01) : 13 - 32
  • [7] The behaviour of asymmetric slim floor steel beams in fire
    Bailey, CG
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 50 (03) : 235 - 257
  • [8] Numerical study on the flexural behaviour of slim-floor beams with hollow core slabs at elevated temperature
    Albero, V.
    Espinos, A.
    Serra, E.
    Romero, M. L.
    Hospitaler, A.
    ENGINEERING STRUCTURES, 2019, 180 : 561 - 573
  • [9] Nonlinear behaviour of unprotected composite slim floor steel beams exposed to different fire conditions
    Ellobody, Ehab
    THIN-WALLED STRUCTURES, 2011, 49 (06) : 762 - 771
  • [10] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Park, Sooyoung
    Kim, Heungyoul
    Hong, Kappyo
    FIRE TECHNOLOGY, 2013, 49 (04) : 907 - 926