Tensile strength of cross-stitch epitenon suture

被引:28
作者
Kim, PT [1 ]
Aoki, M [1 ]
Tokita, F [1 ]
Ishii, S [1 ]
机构
[1] SAPPORO MED UNIV,DEPT ORTHOPED SURG,SAPPORO,HOKKAIDO,JAPAN
关键词
D O I
10.1016/S0266-7681(96)80200-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Using a computerized tensiometer, the mechanical properties of two types of repair in the canine flexor digitorum superficialis tendon were examined, The slope and ultimate tensile strength of a cross-stitch epitenon suture mere compared to those of a simple over-and-over running epitenon suture, Both epitenon sutures were combined with a modified Kessler core suture. Suture material was 6/0 monofilament nylon for the epitenon suture, and 4/0 braided polyester for core suture. Average relative values of individual ultimate tensile strength for the cross-stitch group was 245% compared to that for the running suture group. There was no discrepancy in slope between the two groups.
引用
收藏
页码:821 / 823
页数:3
相关论文
共 10 条
[1]  
Evans HE, 1993, MILLERS ANATOMY DOG, V3rd, P369
[2]   HISTOPATHOLOGICAL CHANGES PRECEDING SPONTANEOUS RUPTURE OF A TENDON - A CONTROLLED-STUDY OF 891 PATIENTS [J].
KANNUS, P ;
JOZSA, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1507-1525
[3]  
Kubota H., 1996, J ORTHOP SCI, V1, P136
[4]  
Lister G D, 1977, J Hand Surg Am, V2, P441
[6]   CYCLIC STRESS-ANALYSIS OF FLEXOR TENDON REPAIR [J].
PRUITT, DL ;
MANSKE, PR ;
FINK, B .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (04) :701-707
[7]   FLEXOR TENDON REPAIR IN ZONE-II WITH A NEW SUTURE TECHNIQUE AND AN EARLY MOBILIZATION PROGRAM COMBINING PASSIVE AND ACTIVE FLEXION [J].
SILFVERSKIOLD, KL ;
MAY, EJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (01) :53-60
[8]   2 NEW METHODS OF TENDON REPAIR - AN INVITRO EVALUATION OF TENSILE-STRENGTH AND GAP FORMATION [J].
SILFVERSKIOLD, KL ;
ANDERSSON, CH .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (01) :58-65
[9]  
UCHIYAMA E, 1991, J JAPANESE ORTHPAEDI, V13, P281
[10]   FLEXOR TENDON REPAIR - SIGNIFICANT GAIN IN STRENGTH FROM THE HALSTED PERIPHERAL SUTURE TECHNIQUE [J].
WADE, PJF ;
WETHERELL, RG ;
AMIS, AA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (02) :232-235