Late perforation of a thoracic aortic Dacron graft by a metallic stent-graft component

被引:6
作者
Cosin, Octavio [1 ]
Rousseau, Herve [1 ]
Otal, Phillipe [1 ]
Cron, Christoff [1 ]
Chabbert, Valerie [1 ]
Joffre, Francis [1 ]
机构
[1] Hop Rangueil, Serv Radiol, F-31059 Toulouse 9, France
关键词
thoracic aorta; Dacron graft; stent-graft; perforation;
D O I
10.1583/06-1881.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To describe a case involving perforation of a previously placed aortic Dacron graft by the uncovered proximal stent of a thoracic stent-graft. Case Report: A 76-year-old man with a surgically treated type A dissection presented with residual type B dissection. Thoracic stent-grafting of the entry site was performed successfully. After 2 years, the patient was admitted for evaluation of a non-pulsating parasternal mass. Computed tomography showed a large, hypodense liquid-like mass affecting the mediastinum up to the subcutaneous tissue. A false aneurysm at the proximal end of the stent-graft was observed arising from an aortic perforation by the uncovered stent. One week later, the mass had almost completely resolved, and the patient has been scheduled for close surveillance. Conclusion: This case illustrated the importance of thoroughly examining the long-term durability and compatibility of prosthetic materials.
引用
收藏
页码:676 / 680
页数:5
相关论文
共 19 条
  • [1] Abul-Khoudoud O, 2004, J ENDOVASC THER, V11, P72
  • [2] PERIGRAFT SEROMA - CLINICAL, HISTOLOGIC, AND SEROLOGIC CORRELATES
    AHN, SS
    MACHLEDER, HI
    GUPTA, R
    MOORE, WS
    [J]. AMERICAN JOURNAL OF SURGERY, 1987, 154 (02) : 173 - 178
  • [3] BILATERAL STERNOCLAVICULAR JOINT SEPTIC ARTHRITIS PRESENTING AS CUTANEOUS ABSCESSES
    ASNIS, DS
    DHALIWAL, GS
    [J]. CLINICAL INFECTIOUS DISEASES, 1994, 19 (05) : 964 - 966
  • [4] Beregi JP, 2003, J ENDOVASC THER, V10, P486, DOI 10.1583/1545-1550(2003)010<0486:ETOACA>2.0.CO
  • [5] 2
  • [6] Endovascular treatment of thoracic aortic disease - Four years of experience
    Bortone, AS
    De Cillis, E
    D'Agostino, D
    Schinosa, LDT
    [J]. CIRCULATION, 2004, 110 (11) : II262 - II267
  • [7] Chabbert V, 2003, J ENDOVASC THER, V10, P494, DOI 10.1583/1545-1550(2003)010<0494:MOOTAS>2.0.CO
  • [8] 2
  • [9] False aneurysms at both ends of a descending thoracic aortic stent-graft: Complication after endovascular repair of a penetrating atherosclerotic ulcer
    Chen, FH
    Shim, WH
    Chang, BC
    Park, SJ
    Won, JY
    Lee, DY
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (02) : 249 - 253
  • [10] Emergency endovascular treatment of a ruptured thoracic aneurysm discovered as a back pulsatile mass
    Collart, F
    Kerbaul, F
    Jop, B
    Magnan, PE
    Bartoli, JM
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 102 (03) : 537 - 538