Evaluation of CES and DFIG unit in AGC of realistic multisource deregulated power system

被引:28
|
作者
Dhundhara, Sandeep [1 ]
Verma, Yajvender Pal [1 ]
机构
[1] Panjab Univ, Dept Elect & Elect Engn, UIET, Chandigarh, India
来源
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS | 2017年 / 27卷 / 05期
关键词
automatic generation control; capacitive energy storage; deregulation; doubly fed induction generators; thyristor controlled phase shifter; LOAD FREQUENCY CONTROL; AUTOMATIC-GENERATION CONTROL; FED INDUCTION GENERATOR; DYNAMIC PARTICIPATION; DIVERSE SOURCES; CONTROLLER; TCPS; SIMULATION; ALGORITHM; IMPACT;
D O I
10.1002/etep.2304
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article discusses evaluation of dynamic contribution of wind turbine unit of doubly fed induction generators (DFIGs) type and capacitive energy storage (CES) in frequency regulation services in 2-area interconnected power system, having diverse thermal-hydro-gas (T-H-G) generating units in deregulated power environment. To obtain optimal dynamic responses of area's frequency oscillations following a small load perturbation, CES/DFIG units have been included in both control areas in coordination with thyristor controlled phase shifter (TCPS).The behavior of DFIGs to enhance dynamic performances of the proposed power system has been investigated by providing inertial support through modified inertial control scheme. The control scheme responds proportionally to frequency variations due to sudden load changes in the power system and uses wind turbine's kinetic energy to provide the inertial control support under several operational conditions. The gain parameters of the integral controller is obtained by using integral square error technique. The performance of the proposed system has been examined in different contract scenarios. Results show that the coordinated action of CES/DFIG units with TCPS unit provide optimal transient performance by arresting the initial dip in area frequencies as well as the power flow deviation in tie-line between the 2 areas. Further, analysis reveals that CES unit response is better and quicker than DFIG unit to damp the system oscillations.
引用
收藏
页数:14
相关论文
共 36 条
  • [31] Frequency Stabilization for Thermal-Hydro Power System with Fuzzy Logic Controlled SMES unit in Deregulated Environment
    Bhateshvar, Y. K.
    Mathur, H. D.
    2014 FOURTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION TECHNOLOGIES (ACCT 2014), 2014, : 536 - 540
  • [32] Reliability evaluation of deregulated power system considering competitive electricity market
    Ehsani, A.
    Ranjbar, A. M.
    Jafari, A.
    Fotuhi-Firuzabad, M.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2007, 31 (B6): : 603 - 616
  • [33] A novel quasi-oppositional harmony search algorithm for AGC optimization of three-area multi-unit power system after deregulation
    Shiva, Chandan Kumar
    Mukherjee, V.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2016, 19 (01): : 395 - 420
  • [34] Automatic generation control of multi-unit multi-area deregulated power system using a novel quasi-oppositional harmony search algorithm
    Shiva, Chandan Kumar
    Mukherjee, Vivekananda
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) : 2398 - 2408
  • [35] Dynamic Coordination Optimization Model of Regional and Provincial AGC Unit Control for Ultra-high Voltage Line Interconnected Power System
    Zhao, Ruifeng
    Yan, Wei
    Zhang, Jinge
    Lu, Jiangang
    Li, Bo
    Wang, Haizhu
    Guo, Wenxin
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3497 - 3506
  • [36] Analytical Evaluation to Power System Oscillation Damping Capability of DFIG-POD Based on Path Damping Torque Analysis
    Li, Shenghu
    Ye, Jianqiao
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2025, 16 (01) : 496 - 511